Technial Description
BRP391 45LED(70~140)
BRP391 55LED(70~140)
BRP391 65LED(70~140)
BRP391 75LED(70~140)
BRP391 90LED(70~140)
BRP392 100LED(70~140)
BRP392 110LED(70~140)
BRP392 120LED(70~140)
BRP392 130LED(70~140)
BRP392 140LED(70~140)
BRP392 155LED(70~140)
BRP392 165LED(70~140)
BRP392 175LED(70~140)
BRP393 185LED(70~140)
BRP393 195LED(70~140)
BRP393 210LED(70~140)
BRP393 220LED(70~140)
BRP393 230LED(70~140)
BRP393 240LED(70~140)
BRP393 250LED(70~140)
BRP393 260LED(70~140)
BRP394 185LED(70~140)
BRP394 195LED(70~140)
BRP394 210LED(70~140)
BRP394 220LED(70~140)
BRP394 230LED(70~140)
BRP394 240LED(70~140)
BRP394 250LED(70~140)
BRP394 260LED(70~140)
BRP394 275LED(70~140)
BRP394 285LED(70~140)
BRP394 295LED(70~140)
BRP394 310LED(70~140)
BRP394 320LED(70~140)
BRP394 330LED(70~140)
BRP394 340LED(70~140)
BRP394 350LED(70~140)
*Maximum Number of Luminaire on MCB 16A Type C
* 1.6 Time of type B for MCB 16A
The electrical circuit Touch current or protective conductor
current (in some cases referred to Earth Leakage Current)
may be greatly dependent upon electrical supply cables used
such as its rating and length, proper connection of electrical
supply cables to luminaires and wiring connection topology
of luminaires to the supply electrical circuit amongst other
site conditions.
Philips Lighting (China) Investment Co., Ltd.
Building No.9, Lane 888 Tianlin Road,
Minhang District, Shanghai, China
Pos talcode: 200233
220-240V
IK08
50/60Hz
*Maximum Number
Power/W
LEDs
of Luminaire on MCB
(max.)
16A Type B
45
40
11 Fixed Driver
55
50
65
60
75
70
90
80
100
90
Non Dimming Version
110
100
120
110
130
120
Dimming version
140
130
155
140
165
150
175
160
185
170
195
180
210
190
Non Dimming Version
220
200
230
210
240
220
Dimming Version
250
230
260
240
185
170
195
180
210
190
220
200
230
210
240
220
250
230
Non Dimming Version
260
240
275
250
285
260
Dimming Version
295
270
310
280
320
290
330
300
340
310
350
320
1 pcs driver
108A/140μs
108A/140μs
46A/250μs
53A/300μs
46A/250μs
53A/300μs
65A/330μs
65A/330μs
RoHS
Inrush current
7.4A/59.8μs
11
Non Dimming Version
46A/440μs
6
5
Non Dimming Version
92A/440μs
3
5
Non Dimming Version
92A/440μs
3
Alternative Program Driver Inrush Current (Dimming version)
2 pcs driver
216A/140μs
216A/140μs
92A/250μs
106A/300μs
92A/250μs
106A/300μs
130A/330μs
130A/330μs
Factory Description
BRP39X LEDaaa/bb cccW 220-240V dddd ee fff gg
x=1 denotes small version housing,
x=2 denotes middle version housing,
x=3 denotes middle plus version housing,
x=4 denotes large version housing;
aaa denotes rated lumen output
E.g. aaa=150, the rated lumen output 15000lm
bb denotes colour temperature
CW=Cool White
NW=Neutral White
WW=Warm White
ccc denotes rated system power
E.g ccc=150, the rated system power 150W
dddd denotes : Driver Type
Driver Type: PSU/PSR/PSD/PSDD/nil
ee Type of insulation protection nil/ Class II
Class I& II (40W ~ 160W)
fff Lens type: DM/DW1/DW2
gg P1 or P7 NEMA socket
Driver Description
Xitanium 75W 0.35-0.7A GL Prog sXt
Xitanium 150W 0.35-0.7A GL Prog sXt
Xi FP 75W 0.2-0.7A SNLDAE 230V S240 sXt
Xi FP 150W 0.2-0.7A SNLDAE 230V S240 sXt
Xi FP 75W 0.2-0.7A SNLCDAE 230V S240 sX
Xi FP 150W 0.2-0.7A SNLCDAE 230V S240 sX
Xi SR 75W 0.2-0.7A SNEMP 230V S240 sXt
Xi SR 150W 0.2-0.7A SNEMP 230V S240 sXt
444100098933

Advertisement

loading

Summary of Contents for Philips BRP392

  • Page 1 Xi FP 150W 0.2-0.7A SNLCDAE 230V S240 sX 65A/330μs 130A/330μs Xi SR 75W 0.2-0.7A SNEMP 230V S240 sXt 65A/330μs 130A/330μs Xi SR 150W 0.2-0.7A SNEMP 230V S240 sXt Philips Lighting (China) Investment Co., Ltd. Building No.9, Lane 888 Tianlin Road, Minhang District, Shanghai, China Pos talcode: 200233...
  • Page 2 产品尺寸/Product Size Standards Ver sion Type Weight/KG L×W×H(mm)Wind force area(㎡) BRP391 ≈5 492*210*86 BRP392 ≈7 492*295*86 0.14 BRP393 ≈8 651*295*86 0.17 BRP394 ≈10 870*295*86 0.25 NEMA Socket Version Type Weight/KG L×W×H(mm)Wind force area(㎡) BRP391 ≈5 492*210*140 BRP392 ≈7 492*295*140 0.14 BRP393 ≈8...
  • Page 3 60245 IEC57 2X1.0mm2 BRP394 BRP391&BRP392&BRP393...
  • Page 4 ∅ 42 ~ 60mm SPD replacement Only for Class I BRP394 BRP391&BRP392 NEMA Socket Note: Must use Philips subsidiary ___short cap to ensure IP66...
  • Page 5 3.Luminaire optical lens cover shall be cleaned with clean water and non-abrasive soap, cleaner or detergent solution. Caution The Luminaire must be used within the applicable product specifications, installation instructions and environmental conditions for storage & operations according to application guidelines provided by Philips for product Warranty to be valid. ‫توصيل األسالك‬ Предупреждения...
  • Page 6 Tránh để vị trí cáp nguồn gần các linh kiện có nhiệt độ cao Đảm bảo nối dây đúng để duy trì phân cực Philips Lighting B.V. sản xuất tất cả bộ điều khiển sử dụng trong bộ đèn này Bộ đèn này được thiết kế cho ứng dụng chiếu sáng ngoài trời Bảo trì...

This manual is also suitable for:

Brp391Brp393Brp394