Sealey SJBEX200.V2 Instruction

Sealey SJBEX200.V2 Instruction

Jacking beams

Advertisement

Quick Links

Your new jack is produced and manufactured to a high standard of dependability and will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
ImpoRTANT: REAd thESE INStRuCtIoNS CAREfuLLy. NotE thE SAfE oPERAtIoNAL REQuIREMENtS, WARNINGS ANd CAutIoNS.
uSE thIS JACK CoRRECtLy ANd WIth CARE foR thE PuRPoSE foR WhICh It IS INtENdEd. fAILuRE to do So MAy CAuSE dAMAGE
ANd/oR PERSoNAL INJuRy ANd WILL INVALIdAtE thE WARRANty. REtAIN thESE INStRuCtIoNS foR futuRE uSE.
1. SAfEty PRECAutIoNS
Ensure the beam is in sound condition and good working order. take action for immediate repair or replacement of damaged parts.
use genuine parts only. the use of improper parts may be dangerous and will invalidate the warranty.
Inspect the beam before each use. do Not use the beam if it is damaged, altered, modified, in poor condition, leaking hydraulic fluid, or
unstable due to missing parts.
do Not alter or modify this beam in any way.
do Not load the beam beyond its rated capacity.
do Not operate the beam if damaged.
do Not allow untrained persons to operate the beam.
do Not use the beam for purposes other than that for which it is intended.
do Not use the centre saddle if the work to be performed can cause
the load to move.
do Not top up hydraulic system with brake fluid. use hydraulic
jack oil only.
use the beam only for its intended purpose.
consult the vehicle manufacturer for the correct lifting locations.
Make sure the vehicle is in park and the handbrake is on before attempting to raise the vehicle.
only use the saddles provided with the jacking beam.
Be sure setup is stable and secure before lifting. Be careful of pinch points.
this is a lifting device only. Make sure the load is centered on saddles before lifting.
the beam can only be used to lift one end of the vehicle.
Ensure that there are no persons or obstructions beneath the vehicle before lowering.
Always lower load slowly and carefully.
When not in use store beam fully lowered.
Ensure all non-essential persons keep a safe distance whilst the beam is in use.
use a qualified person to maintain or repair the beam's hydraulic system.
 WARNING! Failure to heed these precautions may result in loss of load, damage to beam and/or personal injury.
2.
SPECIfICAtIoNS
Fully certified and approved to comply with VoSA requirements. Features two stage
mechanical safety lock and telescopic finger guards to prevent accidental injury. Supplied with
two pairs of aluminium support blocks. Beam has spring loaded flat arms with roller bearings
when unloaded, these support the weight of the beam, allowing the entire unit to run smoothly
along the pit or ramp, but when loaded locate the unit firmly. Wide lift configuration meets
VoSA recommendation for lifting on jacking point.
Model . . . . . . . . . . . . . . . . . . . . .SJBEX200.V2. . . . . . . . . . . .SJBEX300
capacity:. . . . . . . . . . . . . . . . . . .2ton . . . . . . . . . . . . . . . . . . .3ton
Support Arm reach: . . . . . . . . . .780 - 1075mm . . . . . . . . . . .780 - 1075mm
Beam lift: . . . . . . . . . . . . . . . . . .95 - 300mm . . . . . . . . . . . . .95 - 300mm
load Arm reach: . . . . . . . . . . . .850 - 1600mm . . . . . . . . . . .850 - 1600mm
Net Weight:. . . . . . . . . . . . . . . . .94kg . . . . . . . . . . . . . . . . . . .102kg
3. PREPARAtIoN
WARNING! These jacking beams weigh 94kg and 102kg respectively. Seek
assistance before attempting to locate jacking beam on ramp or inspection pit
runners.
3.1.
Locating jacking beam.
3.1.1. Extend the roller arms to the correct width for ramp or pit runners. See fig.3 overleaf.
3.1.2. With the beam central on the ramp/pit and the rollers located on the runners, tighten
the roller arms set bolts. (Fig.2)
3.1.3
Adjust the spring tension on all four rollers (see fig.3 overleaf) so that the rollers
will just support the weight of the jacking beam on its own and allow it to travel
freely over the ramp/pit. Note that too much spring tension will cause the rollers to
jam against the side arms. When the jacking beam is in use the weight of the vehicle
will overcome the spring tension, pushing the rollers upwards and allowing the
jacking beam to settle onto the two roller arms.
3.1.4. Before use you must remove the transportation plug and fit the supplied vent valve
in its place. (Fig.1)
INStructIoNS For:
JACKING BEAMS
ModElS:
Original Language Version
SJBEX200.V2 & SJBEX300
fig.1
trANSPortAtIoN PluG
rEMoVE ANd rEPlAcE WItH VENt
VAlVE BEForE uSE.
SJBEX200.V2, SJBEX300
fig.2
Issue: 4 - 16/10/09

Advertisement

loading

Summary of Contents for Sealey SJBEX200.V2

  • Page 1 VoSA recommendation for lifting on jacking point. Model .....SJBEX200.V2... .SJBEX300 capacity:.
  • Page 2 4.2.8. Make sure the locking lever is engaged, if it is not engaged you need to raise or lower the beam to the closest locking point,and check the locking lever engages. 4.2.9. to lower the vehicle follow the procedure outlined in 4.1.3 Jacking Beam controls. MAINtENANCE Original Language Version SJBEX200.V2, SJBEX300 Issue: 4 - 16/10/09...
  • Page 3 WARRANty: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INfoRMAtIoN: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole uK distributor, Sealey Group, www.sealey.co.uk...

This manual is also suitable for:

Sjbex300