Download Print this page
Panasonic LS-H F-A Series Instruction Manual
Panasonic LS-H F-A Series Instruction Manual

Panasonic LS-H F-A Series Instruction Manual

Laser sensor head

Advertisement

Quick Links

Laser Sensor Head
LS-H□F-A
Thank you very much for purchasing Panasonic products. Read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use
products which meet laws and standards, such as OSHA, ANSI or
IEC etc., for personnel protection applicable in each region or country.
Although this product corresponds to a Class 1 laser product, it is
dangerous to see the laser beam which has been passed through a
WARNING
viewing optical system such as a lens etc. Hence, please avoid this.
Use of control or adjustment or performance of procedures other
than those specified in this instruction manual may result in
hazardous radiation expose.
1
FOR SAFE USE OF A LASER PRODUCT
With regard to safety of laser products, IEC 60825-1
products' has been stipulated by the IEC (International Electrotechnical Commis-
sion). In IEC 60825-1
, laser products are divded into classes corresponding
-2014
to the degree of danger of the laser component, and preventive measures to
assure safety which should be taken with each class are stipulated.
This product is classified as a 'Class 1 laser product' by IEC 60825-1
This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated
June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under
the FDA (Food and Drug Administration). For details, refer to the Laser Notice No. 50.
● Classification of laser product (IEC 60825-1
Classification
Class 1
Safe under reasonably foreseeable conditions.
● Summary of the safety precautions for user of a laser product (IEC 60825-1
Class
Not required but recommended for applications that involve direct
Laser safety officer
viewing of the laser beam
Remote interlock
Key control
Beam attenuator
protection
Emission indicator
device
Warning signs
Beam path
Specular reflection
Eye protection
Protective clothing
Training
Note: This table is intended to provide a convenient summary of precautions. See text of IEC
standard for complete precautions.
The following labels are affixed on this product in accordance with the FDA
and IEC 60825-1
standard.
-2014
Warning label
(Label based on FDA)
<Label position>
Direction
of laser
emission
Note: When this product is used based on JIS / IEC standard, affix the accessory explanation label
on the 'Label based on FDA'.
・ Laser emission indicator (green)
While laser is emitted, the laser emission indicator (green) of the sensor head
lights up.
This indicator is visible even when wearing laser protective glasses.
Direction of
laser emission
INSTRUCTION MANUAL
Conforming to FDA
MJE-LSHFA No.0059-45V
'Safety of laser
-2014
)
-2014
Description of hazard class
1
Not required
Not required
Not required
Not required
Not required
Not required
No requirements
No requirements
Not requirements
No requirements
(Label based on IEC 60825-1
-2014
Direction
of laser
emission
Operation indicator (Orange)
Laser emission indicator (Green)
2
SPECIFICATIONS
Type
Item
Model No.
Applicable amplifier
H-SP mode
Sensing
FAST mode
range
STD mode
(Note 2)
U-LG mode
Operation indicator
Laser emission indicator
Ambient temperature
Ambient humidity
Emitting element
Material
Cable
Weight
Accessories
Notes: 1)
The model No. of retroreflective type sensor with the suffix '-Y' is the sensor without the RF-330
reflector. Arrange the reflector separately.
(e.g.) LS-H91F-A-Y
2)
Configure the mode settings in the applicable amplifier LS-400 series.
3
CAUTIONS
This product has been designed to meet the specifications when it is used
along with the optional exclusive amplifier. If an amplifier other than the
exclusive amplifier is used, not only the specifications may not be met, but it
may also be a cause for malfunction or break down. Hence, please ensure to
use this product along with the optional exclusive amplifier.
.
-2014
This product has been developed / produced for industrial use only.
Always use the sensor with the connector to be joined to the amplifier.
Make sure that the power is off while wiring to the amplifier.
In case noise generating equipment (switching regulator, inverter motor etc.)
is used in the vicinity of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that the
frame ground (F.G.) terminal of the power supply is connected to an actual
)
-2014
ground.
Do not use the sensor during the initial transient time (0.5 sec.) just after the
power supply is switched on.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Take care that the sensor head is not directly exposed to fluorescent lamp
from a rapid-starter lamp or a high frequency lighting device, as it may affect
the sensing performance.
The sensor head cable cannot be extended.
Make sure that stress is not applied directly to the sensor head cable joint.
This sensor is suitable for indoor use only.
Do not allow any water, oil fingerprints, etc., which may refract light, or dust,
dirt, etc., which may block light, to stick to the emitting / receiving surfaces of
the sensor head. In case they are present, wipe them with a clean, soft cloth
or lens paper.
Do not use the sensor in vaporous, dusty or corrosive gas atmospheres.
Take care that the sensor does not come in contact with water, oil, grease or
organic solvents, such as, thinner, etc.
Make sure that the power is off while cleaning the emitting / receiving
windows of the sensor head.
)
Coaxial retroreflective type
LS-H91F-A (Note 1)
LS-400 series
0.1 to 1m
0.1 to 1m
0.1 to 3m
0.1 to 5m
Orange LED (Lights up when amplifier output is ON)
Green LED (Lights up when laser is emitted)
-10 to +55℃ (No dew condensation or icing allowed), Storage: -20 to +70℃
35~85% RH, Storage: 35~85% RH
Red semiconductor laser Class 1 (FDA / IEC / JIS standard)
(Max. output: 1mW or less, Peak emission wavelength: 655nm)
Enclosure: PBT (Attachment: PEI), Lens cover: Acrylic
2
0.1mm
shielded cable, 2m long
30g approx.
Connector for amplifier: 1 pc.
Connector for amplifier: 1 pc.
RF-330 (Reflector): 1 pc.
Explanation label (JIS) : 1 pc.
Explanation label (JIS) : 1 pc.
Diffuse reflective type
LS-H21F-A
30 to 150mm
30 to 150mm
30 to 250mm
30 to 500mm

Advertisement

loading

Summary of Contents for Panasonic LS-H F-A Series

  • Page 1 Orange LED (Lights up when amplifier output is ON) Laser emission indicator Green LED (Lights up when laser is emitted) Thank you very much for purchasing Panasonic products. Read this Instruction Ambient temperature -10 to +55℃ (No dew condensation or icing allowed), Storage: -20 to +70℃...
  • Page 2 Marking. As for all other models, please contact our office. http://panasonic.net/id/pidsx/global Overseas Sales Division (Head Office) 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Phone: +81-568-33-7861 FAX: +81-568-33-8591 About our sale network, please visit our website. PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2017...

This manual is also suitable for:

Ls-h91f-aLs-h21f-a