Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Wear Eye
Refer to Instruction
Protection
Manual
1. SAFETY
Replace damaged parts. Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.
Keep the drainer clean and in good condition for best and safest performance.
Wear appropriate protective clothing.
Use drainer in an appropriate working area for its function. Keep area clean and tidy and free from unrelated materials and ensure
there is adequate lighting.
Ensure the floor is not slippery and wear non slip shoes.
Keep children and unauthorised persons away from the working area.
Dispose of waste liquids in accordance with local authority regulations.
WARNING! DO NOT allow uncontrolled discharge of fluids thus polluting the environment.
DO NOT position drainer in such a way that it will cause potential hazards when moving, holding
for draining or storing.
IMPORTANT: AK450DX must be used in conjunction with a wall mounted air pump, model no: AK450DP
in order to discharge waste oil (not supplied with this unit).
2. INTRODUCTION
AK457D: Steel fabricated 75ltr reservoir and telescopic steel funnel fitted with grid filter. Gravity drain using brass tap on rear of unit. Includes full
drum indicator.
AK450DX: 75ltr reservoir and telescopic funnel fitted with grid filter. Fitted with female dry-fit coupling for connection to Model no: AK450DP
Pump-Away Station. Includes full drum indicator.
3. SPECIFICATION
Model No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AK457D . . . . . . . . . . . . . . . . . . . . . . . AK450DX
Maximum Capacity: . . . . . . . . . . . . . . . . . . . . . . 75ltr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75ltr
Minimum Height: . . . . . . . . . . . . . . . . . . . . . . . . 1180mm . . . . . . . . . . . . . . . . . . . . . . . . 1180mm
Maximum Height:. . . . . . . . . . . . . . . . . . . . . . . . 1750mm . . . . . . . . . . . . . . . . . . . . . . . . 1750mm
Length:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 590mm . . . . . . . . . . . . . . . . . . . . . . . . . . 590mm
Width:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600mm . . . . . . . . . . . . . . . . . . . . . . . . . . 600mm
Discharge: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gravity . . . . . . . . . . . . . . . . . . . . . . . . .Air Pump
Nett Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29kg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29kg
4. ASSEMBLY
4.1.
Unscrew the complete axle assembly from the transportation position. Use the nuts, bolts, and washers that are provided to fit the axle
assembly and position the castor wheels as illustrated in the parts diagram.
4.2.
Screw the drainage tube (item 3) into the collection bowl (item 2).
4.3.
Introduce the drainage tube through the height adjustment adaptor into the reservoir and tighten the scalloped hand wheel (item 4).
4.4.
Place the filter into the collection bowl (item 1).
5. OPERATION
5.1.
Collection of waste oil
5.1.1. If unit has been used to drain a previous vehicle, check the oil level indicator float to ensure there is sufficient remaining capacity left
before you use the unit. If model AK457D is empty, ensure the evacuation tap is closed before you use the unit.
5.1.2. Place the unit under the raised vehicle and adjust the collection bowl to the desired height and tighten the scalloped hand wheel
of the adjustable height adaptor.
5.2.
Evacuation of waste oil from unit. WARNING! ensure all waste is disposed of in accordance with local regulations.
5.2.1. AK457D position the gravity drain tap over a suitable outlet and open the tap.
5.2.2. AK450DX take the discharge hose of wall mounted pump unit AK450DP and connect the female coupling to the male coupling
of the pan unit and evacuate waste accordingly.
© Jack Sealey Limited
INSTRUCTIONS FOR:
OIL DRAINER UNITS
AK457D, AK450DX
MODEL NO'S:
Wear Protective
Gloves
Original Language Version
AK457D,AK450DX
Issue:3(L) - 31/05/17

Advertisement

loading

Summary of Contents for Sealey AK457D

  • Page 1 (not supplied with this unit). 2. INTRODUCTION AK457D: Steel fabricated 75ltr reservoir and telescopic steel funnel fitted with grid filter. Gravity drain using brass tap on rear of unit. Includes full drum indicator. AK450DX: 75ltr reservoir and telescopic funnel fitted with grid filter. Fitted with female dry-fit coupling for connection to Model no: AK450DP Pump-Away Station.
  • Page 2 179.04356 M10 x 25 Hexagon bolt, DIN933 179.04462 Axle 179.04333 Wheel 179.19786 Gravity drain valve Model AK457D 179/19774 Male quick release connector Model AK450DX 179/04398 Float indicator Environmental Protection Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.

This manual is also suitable for:

Ak450dx