Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
WARNING! Ensure any Health & Safety, Government, or local authority regulations are adhered to when using this equipment.
!
Familiarise yourself with the application and limitations, as well as the potential hazards, of the generator.
"
Maintain the generator in good condition (use an authorised service agent). Replace or repair damaged parts. Use genuine parts only.
"
Unauthorised parts may be dangerous and will invalidate the warranty.
This generator is designed and manufactured for specific applications. Do not attempt to modify the unit or use it for any application for
"
which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey dealer.
WARNING! DO NOT exceed the Wattage/Amperage capacity of the generator. Add rated wattage of all devices intended for connection
!
at any one time, the total must not exceed rated wattage of generator (see specifications). In most cases the rated wattage of an electrical
device can be found on the nameplate. If the nameplate only gives voltage and amperage, multiply the two to give rated wattage (Volts x
Amps = Watts)
WARNING! Generator exhaust gases contain deadly carbon monoxide which must not be inhaled. Always allow sufficient ventilation.
! !
WARNING! If you decide to use an Earth Leakage Circuit Breaker (also referred to as an RCD or Ground Fault Circuit Interrupter),
! !
it is imperative that the neutral end of the power winding is connected to the frame of the generator set and that the earth lug on the
frame is connected with a low impedance connector to the local earth via an earth spike or local protective earth conductor. This
connection should only be attempted by a qualified electrician, after first having consulted your local dealer.
DANGER! This generator is designed for outdoor use only. To use the generator inside any building or enclosure, including the
# #
generator compartment of a caravan, may result in fire or an explosion. No user performed modifications, including venting of
the exhaust and/or cooling ventilation, will eliminate the danger.
DANGER! If this unit is used for back-up power in the event of a commercial power failure, the following steps must be taken.
# #
Before connecting the generator to the electrical system, open the main circuit breaker to isolate the generator and system from
the commercial electric supply. Failure to do this may result in damage to the generator and may result in serious injury or fatality,
due to a back-feed of electrical energy.
DANGER! The generator produces a very powerful voltage that can cause a severe electrical shock. Avoid contact with bare
# #
wires, terminals etc. Never allow any unqualified person to operate or service the generator.
WARNING! Petrol is highly flammable and petrol vapour is explosive. Do not permit smoking, naked flames, sparks or heat in the
! !
vicinity while handling petrol. Avoid spilling petrol onto a hot engine. Comply with all laws regulating storage and handling of fuels.
WARNING! NEVER refuel when the engine is running or when the engine is hot. Allow cool down time.
! !
Operate the generator only on level surfaces (maximum allowable tilt is 10º) and where it will not be exposed to excessive moisture, dirt
"
or corrosive vapours or be in the proximity of combustible material (flammable liquids, solids or gases).
Remove ill fitting clothing, ties, watches, rings and other loose jewellery and contain long hair. Wear appropriate protective clothing.
"
Keep non-essential persons away from the working area.
"
WARNING! Never start or stop the generator while electrical loads are connected and switched on. Start the engine, let it
! !
stabilise, then connect the electrical load. To stop engine, disconnect the electrical load and let engine stabilise before switching off.
WARNING! Do not use worn, bare, frayed or otherwise damaged electrical cables with the generator. To do so may result in electric shock.
! !
DO NOT use the generator for any purpose other than that for which it is designed.
$
DO NOT operate the generator if any parts are missing or damaged, as this may cause failure and/or personal injury.
$
DO NOT over-fill fuel tank. Always leave room for fuel to expand.
$
DO NOT operate in the rain.
$
# DANGER! Do not tamper with the engine governed speed setting. Higher operating speeds are dangerous and increase the risk
of personal injury and/or equipment damage. The generator supplies the correct rated frequencies and voltage only when
running at the correct governed speed. Incorrect frequency and/or voltage can damage some connected electrical loads.
Operating at excessively low speeds may result in shortened engine life. Over-speeding will invalidate the warranty.
DO NOT operate the generator when you are tired, or under the influence of alcohol, drugs or intoxicating medication.
$
DO NOT store generator with fuel in tank where petrol vapours might reach an open flame or spark.
$
2. INTRODUCTION & SPECIFICATIONS
2.1 These generators are powered by Honda OHV GX engines. The units offer a quiet and refined power delivery. Models HG65.30,
HG90.44 and HG130.74 power industrial quality alternators and are for industrial or arduous applications.
SPECIFICATIONS
Model No. . . . . . . . . . . . . . . . . . .HG55.28.V3 . . . . . . . . . . . . .HG65.30.V2 . . . . . . . . . . . . .HG90.44.V2 . . . . . . . . . . . . . HG130.74.V3
Power Unit: . . . . . . . . . . . . . . . . . . . . . . .5.5hp . . . . . . . . . . . . . . . . . .6.5hp . . . . . . . . . . . . . . . . . .9.0hp . . . . . . . . . . . . . . . . . . . . 13hp
Motor Type . . . . . . . . . . . . . . . .Honda GX160 . . . . . . . . . . .Honda GX200 . . . . . . . . . . . .Honda GX270 . . . . . . . . . . . . . Honda GX390
Output: . . . . . . . . . . . . . . . . . .230V/110V 50hz . . . . . . . . .230V/110V 50hz . . . . . . . . . .230V/110V 50hz . . . . . . . . . . . 230V/110V 50hz
Current Rating: . . . . . . . . . . . . . . .10.9A/16.0A . . . . . . . . . . . . . .12.2A/16A . . . . . . . . . . . . .16.1A/32.2A . . . . . . . . . . . . . . 23.9A/47.8A
Continuous Power Rating: . . . . . . . . . . .2500W . . . . . . . . . . . . . . . . .2900W . . . . . . . . . . . . . . . . .3700W . . . . . . . . . . . . . . . . . . 5500W
Fuel Tank Capacity: . . . . . . . . . . . . . . . . .3.6ltr . . . . . . . . . . . . . . . . . .3.6ltr . . . . . . . . . . . . . . . . . . .6.0ltr . . . . . . . . . . . . . . . . . . . . 6.5ltr
Running time: . . . . . . . . . . . . . . . . . . . . .3.1hr . . . . . . . . . . . . . . . . . .2.7hr . . . . . . . . . . . . . . . . . . .3.2hr . . . . . . . . . . . . . . . . . . . . 2.7hr
Noise Rating LWA: . . . . . . . . . . . . . . . . . .94dB . . . . . . . . . . . . . . . . . .96dB . . . . . . . . . . . . . . . . . . .97dB. . . . . . . . . . . . . . . . . . . . 97dB
Dry Weight: . . . . . . . . . . . . . . . . . . . . . . .38kg . . . . . . . . . . . . . . . . . .41kg . . . . . . . . . . . . . . . . . . .60kg . . . . . . . . . . . . . . . . . . . . 82kg
HG65.30.V2,
PORTABLE GENERATORS
INSTRUCTIONS FOR MODELS:
HG90.44.V2,
HG55.28.V3, HG65.30.V2, HG90.44.V2, HG130.74.V3. - 1 - 160307
HG130.74.V3

Advertisement

loading

Summary of Contents for Sealey HG55.28.V3

  • Page 1 " which it is not designed. If you have any questions regarding the application of the unit please contact your local Sealey dealer. WARNING! DO NOT exceed the Wattage/Amperage capacity of the generator. Add rated wattage of all devices intended for connection at any one time, the total must not exceed rated wattage of generator (see specifications).
  • Page 2 3.6.2. Allow the engine to run unloaded for 1 - 2 mins. 3.6.3. Stop engine by moving the engine switch to the 0 position, figs 1 & 3. 3.6.4. Turn off the fuel valve, fig .2. HG55.28.V3, HG65.30.V2, HG90.44.V2, HG130.74.V3. - 1 - 160307...
  • Page 3: Maintenance

    Ensure the spark plug HT lead has been disconnected prior to commencing maintenance. " The oil, air filter and spark plug must be changed regularly. All other maintenance must be carried out by qualified staff, contact your local Sealey service agent. Maintenance period First month Every 3...
  • Page 4: Storing The Generator Set

    5.6.2. Crank the engine several times in order to circulate the the oil into the cylinder, then refit the spark plug. 5.6.3. Slowly pull the recoil starter cord until some resistance is felt, then keep pulling until the arrow on the starter pulley aligns with the hole on the recoil starter. HG55.28.V3, HG65.30.V2, HG90.44.V2, HG130.74.V3. - 1 - 160307...
  • Page 5: Troubleshooting

    BS ISO 8528 - Generating Sets upon request to Jack Sealey Ltd. 2002/95/EC RoHS Directive For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products. 2002/96/EC WEEE Directive NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

This manual is also suitable for:

Hg65.30.v2Hg90.44.v2Hg130.74.v3