Download Print this page

Sealey SWP20 Instructions

Submersible water pump

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.
SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY. F
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and
all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety
devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD
(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are
plugged into an electrical supply not protected by an RCCB. If in doubt consult a professional electrician. You may obtain a Residual Current
Device by contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity At Work Act 1989 requires all portable electrical appliances, if used on a business premises, to be tested by
a qualified Electrician at least once a year by using a Portable Appliance Tester (PAT).
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance,
and the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3.
Ensure the insulation on all cables and the product itself is safe before connecting to the mains power
supply. The pump and cable are designed for submerging in water and as such must not be
tampered with (If in doubt, contact a qualified electrician).
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage,
especially power connections, to ensure that none are loose.
1.1.6. Important: Ensure the voltage marked on the product is the same as the electrical power supply
to be used, and check that plugs are fitted with the correct capacity fuse. A 13Amp plug may require
a fuse smaller than 13Amps for certain products (subject to 1.1.10. below) see fuse rating at right.
1.1.7. DO NOT pull or carry the powered appliance by its power supply lead.
1.1.8. DO NOT pull power plugs from sockets by the power cable.
1.1.9. DO NOT use worn or damaged leads, plugs or connections. Immediately replace or have repaired by
a qualified Electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off
and fit a new plug according to the following instructions (discard old plug safely).
(UK only - see diagram at right). Ensure the unit is correctly earthed via a three-pin plug.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
After wiring, check there are no bare wires, that all wires have been correctly connected and that the wire restraint is tight.
1.1.10. Only allow the minimal amount of pump cable to enter water or wet areas. The electrical cable is designed for use in water and must
not be substituted. If damaged contact a qualified electrician.
1.1.11. Extension cable use. Only use a cable designed for use with water equipment. Contact your dealer or a qualified electrician
for advice. Ensure water is kept clear of electrical mains power supply. DO NOT touch switch or plug with wet hands.
1.2
GENERAL SAFETY
WARNING! Pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and regulations.
F
Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.
!
WARNING! Disconnect the pump from the mains power before changing accessories, servicing or performing any maintenance.
F
Maintain the pump in good condition (use an authorised service agent). Keep the pump clean.
!
Replace or repair damaged parts. Use genuine parts only. Non authorised parts may be dangerous and will invalidate the warranty.
!
Only use for pumping clean cold or warm water, (NOT exceeding 35
!
If pump is used to pump water from a well, drain or deep receptacle, take adequate precaution to stop persons and animals from falling in.
!
Use the built in handle to lower or remove the pump. It may be necessary to attach a suitable rope or pulley to the handle.
!
If the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to
!
operate above the solid matter. Sand and such substances will reduce working life of pump, and invalidate your warranty.
In flood situations, user is responsible for ensuring that appropriate back up procedures, alarms etc are
!
correctly installed in case of pump failure.
In swimming pool, fish ponds, etc, ensure location is clear of people and animals, (including removal of fish from pond). Note: this pump is not
!
designed for continuous use in a fish pond or similar water feature or display.
DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.
&
DO NOT use the pump for any purpose other than for which it is designed.
&
DO NOT use to pump chemicals, fuels or salt water.
&
DO NOT use to pump septic tanks or settling pits. DO NOT pump any liquids other than water.
&
DO NOT operate pump out of water. The pump pick up area must be completely submerged during operation.
&
DO NOT exceed the maximum submersible depth.
&
DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.
&
 WARNING! It is the user’s responsibility to read, understand and comply with the following:
p
INSTRUCTIONS FOR:
SUBMERSIBLE WATER PUMP
Models: SWP20 & SWP20A
C).
O
Yellow & Green
Earth wire
Blue
Neutral
wire
FUSE RATING
THIS PRODUCT MUST BE FITTED
5 Amp FUSE
WITH A:
Model -
SWP20, SWP20A. - 2 - 011203
Brown
Live
wire
wire
restraint

Advertisement

loading

Summary of Contents for Sealey SWP20

  • Page 1 SUBMERSIBLE WATER PUMP Models: SWP20 & SWP20A Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
  • Page 2 The sealant is harmless to humans, but may effect pond life. In such an eventuality, switch the pump off, remove it from the water and clear the oily film. Contact your local Sealey service agent for pump repair.
  • Page 3 We, the sole importer into the UK, declare that the products listed below are in conformity with the following EEC standards and directives The construction file for these products are held by the Manufacturer and may be inspected, by a national authority, SUBMERSIBLE WATER PUMP upon request to Jack Sealey Ltd. For Jack Sealey Ltd. Models: SWP20, SWP20A.

This manual is also suitable for:

Swp20a