Download Print this page
Panasonic SL-JK Instruction Manual
Panasonic SL-JK Instruction Manual

Panasonic SL-JK Instruction Manual

Cable end socket-branch hook-up connector / socket-branch hook-up connector

Advertisement

Quick Links

Thank you very much for purchasing
INSTRUCTION
Panasonic products. Read this Instruc-
MANUAL
tion Manual carefully and thoroughly for
Sensor & Wire-saving Link System S-LINK
the correct and optimum use of this
Flexible Wire-saving System S-LINK V
product. Kindly keep this manual in a
Cable End Socket-branch
Socket-branch
convenient place for quick reference.
Hook-up Connector
Hook-up Connector
SL-JK
SL-JK1
MJEC-SLJK No.0101-04V
PRODUCT OUTLINE
This product is a hook-up connector for the S-LINK exclusive flat cable
(0.5mm
).
2
SL-JK is for connection at the cable end, whereas SL-JK1 can be connected
anywhere on the flat cable for 'T'-branching.
Example of SL-CH to I/O device connection
By hooking-up SL-JK or SL-JK1 on the I/O device side flat cable of the
S-LINK I/O device SL-CH
and using the optional 4-pin type snap male
connector SL-CP1, SL-CP2 or SL-CP3, various I/O devices can be quickly
connected to the S-LINK system.
I/O device (sensor, relay, etc.)
SL-CH
SL-CP1 or
SL-CP2
SL-JK1 (Blue)
(for 'T'-branching)
SL-JK (Light blue)
(for cable end)
Example of S-LINK device connection
By hooking-up SL-JK or SL-JK1 on the S-LINK exclusive flat cable and using
the optional 4-pin type snap male connector SL-CP2 (for hook-up of 0.3mm
cable), 0.3mm
2
cable attached S-LINK devices can be quickly connected.
Further, the S-LINK devices can also be disconnected as per requirement.
SL-CP2
for hook-up of
0.3mm
cable
2
SL-JK1 (Blue)
(for 'T'-branching)
S-LINK direct hook-up
photoelectric sensor
Sensor block
SL-BMJ
CAUTIONS
Ensure that hook-up is done in the power supply off condition.
Do not hook-up in a cold environment.
Make sure to use the S-LINK exclusive flat cable (SL-RCM100 ,
SL-RCM200) as the cable to which SL-JK or SL-JK1 is hooked-up.
Never reuse a hook-up connector. Its performance cannot be guaranteed.
COMPONENT STRUCTURE
SL-JK (for hook-up of 0.5mm
cable)
SL-JK1 (for hook-up of 0.5mm
2
For cable end
Housing (Light blue)
Housing (Blue)
Cover (Light blue)
Cover (Blue)
Wall
+24V indication lines
S-LINK
S-LINK V
T
SL-JK
SL-JK1
0.5mm
S-LINK
2
SL-JK1 T
SL-JK
SL-CH
S-LINK
SL-CH
SL-CP1 SL-CP2
SL-CP3
SL-CH
SL-CP1
SL-CP2
SL-JK1
(T
)
SL-JK
SL-CP1
S-LINK
S-LINK
)
SL-CP2(0.3mm
2
0.3mm
2
S-LINK
SL-CP2
0.3mm
2
SL-JK1
(T
)
S-LINK
SL-A
SL-BMJ
S-LINK
SL-RCM200
SL-JK 0.5mm
SL-JK1 0.5mm
2
+24V
HOOK-UP PROCEDURE
Step
Place the S-LINK exclusive flat cable in the cover and press it so that it is
held by the four hooks.
Caution
Hook
SL-JK1 (for 'T'-branching)
SL-JK1 (Blue)
+24V indication lines
Set the housing in the cover and press to fit it.
I/O device
(relay, sensor, etc.)
Cover
SL-CP1 or SL-CP2
Since the width
confirm that the housing and the cover engage properly when the housing is set.
In case of SL-JK (for cable end),
after fitting, please confirm from the
2
confirmation window of the cover
that the cable is sufficiently inserted
so that its end is not visible.
Using always the exclusive hook-up pliers (SL-JP ), hold the convex
Sensor block
portion of the connector between the guides of the pliers and squeeze till a
SL-BM
click is felt.
Precautions to be taken when using the exclusive hook-up pliers
The convex portions and the guides of the
exclusive hook-up pliers are aligned.
Convex
portion
Convex
portion
The pliers are set such that there is no gap
2
cable)
between the guides and the connector.
For 'T'-branching
Correct
The connector should be set such that it
+24V indication lines
touches the rear end of the guides.
S-LINK
SL-JK1 T
4
SL-JK1
+24V
SL-CP2
4
SL-JK
SL-BM
SL-RCM100
2
T
+24V
Description
[Cover top view]
+24V line mark
Please make sure to fix the flat cable so that its brown
wire (+24V) is towards the side which has the
and the +24V indication lines.
+24V indication lines
SL-JK (for cable end)
Hook
Brown (+24V)
+24V indication lines
Note: Fix the cable such that it touches the wall of the cover.
Brown (+24V)
Housing
, in the above figure, is different on the left and the right sides, please
SL-JK (Light blue)
(for cable end)
Brown (+24V)
[Exclusive pliers: SL-JP ]
Convex portion
Convex portion
The exclusive hook-up pliers are held at
right angle to the cable and squeezed.
Guides
Projections
Incorrect
If the connector is held between the projections
of the guides, correct hook-up is not possible.
4
+24V
+24V
+24V
+24V
SL-JK
+24V
+24V
+24V
1
SL-JK
+24V
SL-JP
SL-JP
CONNECTION OF 4-PIN TYPE SNAP MALE CONNECTOR (SL-CP1, SL-CP2, SL-CP3)
Step
The optional 4-pin type snap male connector SL-CP1 (for 0.08 to 0.2mm
cable), SL-CP2 (for 0.3mm
hooked-up on the I/O device cable.
mark
Wall (Note)
Hook
Please refer to the Instruction Manual enclosed with the 4-pin type snap male connector
SL-CP1, SL-CP2 or SL-CP3 for its hook-up procedure.
Connect the 4-pin type snap male connector to the hook-up connector
SL-JK (Light blue)
SL-JK or SL-JK1.
Reconfirm that there is no miswiring.
Brown (+24V)
SL-JK or SL-JK1
Hook (Note 1)
Terminal Nos.
(Reverse side)
(Note 2)
SL-CP1 or SL-CP2
Notes: 1) Since the hook-up connector and the 4-pin type snap male connector have
Confirmation
window
directionality, please ensure to connect such that the hook and the locking hole
engage.
2) Terminal Nos, are marked on each connector. Please confirm that the respective
terminal Nos, match when the connectors are connected.
Please refer to the S-LINK Design Manual and Construction Manual for details of the
complete S-LINK system.
Panasonic Industry Co., Ltd.
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
https://industry.panasonic.com/
Please visit our website for inquiries and about our sales network.
Panasonic Industry Co., Ltd. 2024
April, 2024
4
4
SL-CP2 (0.3mm
2
1
4
SL-CP1 SL-CP2
SL-CP3
SL-JK
SL-JK
+24V
SL-JK
2
SL-CP1
SL-CP2
1
4
2
S-LINK
"
"
S-LINK V
Panasonic Industry Co., Ltd. 2024
Description
2
cable) or SL-CP3 (for 0.5mm
2
cable) is
SL-CP1 or SL-CP2
I/O device cable
Locking hole (Note 1)
Terminal Nos. (Note 2)
PRINTED IN JAPAN
SL-CP1 SL-CP2 SL-CP3
SL-CP1 (0.08 0.2mm
)
2
)
SL-CP3 (0.5mm
2
)
SL-CP1
SL-CP2
SL-CP1 SL-CP2
SL-CP3
SL-JK1
SL-JK1
1
1
2
S-LINK
S-LINK
S-LINK V
2

Advertisement

loading

Summary of Contents for Panasonic SL-JK

  • Page 1 Example of SL-CH to I/O device connection SL-CP1, SL-CP2 or SL-CP3 for its hook-up procedure. Brown (+24V) By hooking-up SL-JK or SL-JK1 on the I/O device side flat cable of the Connect the 4-pin type snap male connector to the hook-up connector SL-JK (Light blue)
  • Page 2 SL-CP2 SL-CP3 +24V ( 1) +24V SL-JK SL-JK1 SL-CP1 SL-CP2 S-LINK SL-JK S-LINK SL-JK SL-CP2 (0.3mm 0.3mm +24V S-LINK SL-BM 0.3mm SL-JP SL-JP S-LINK SL-A SL-BMJ S-LINK SL-RCM100 SL-RCM200 SL-JK (0.5mm SL-JK1 (0.5mm Panasonic Industry Co., Ltd. 2024 +24V +24V...

This manual is also suitable for:

Sl-jk1