Download Print this page

KitchenAid KHTU100K Dimension Manual

30" and 36" traditional series vented and non- vented range hoods

Advertisement

Quick Links

PRODUCT MODEL NUMBERS
KHTU160K
KHTU100K
Electrical: 120-volt, 60-Hz, AC-only, 15-amp.
electrical supply. Use copper wire only. A time-
delay fuse or circuit breaker and separate circuit
is recommended.
VENTING REQUIREMENTS
3-1/4" x 10"
(8.3 cm x 25 cm)
vent through
the roof
Roof venting
Recommended
standard fittings
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
®
30" and 36" Traditional Series Vented and Non- Vented
Range Hoods
OVERALL DIMENSIONS
Note: Underside of hood must be a minimum of
24" (61 cm) from cooking surface.
4-3/4"
(12.1 cm)
5-1/16"
(12.9 cm)
3-1/4" x 10"
(8.3 cm x 25 cm)
vent through
the wall
Wall venting
3-1/4" x 10"
(8.3 cm x 25 cm)
90° elbow
= 5 ft. (1.5 m)
3-1/4" x 10"
(8.3 cm x 25 cm)
flat elbow
= 12 ft. (3.7 m)
3-1/4" x 10"
(8.3 cm x 25 cm)
wall cap
= 0 ft. (0 m)
3-3/16"
(8.1 cm)
13-3/8"
(34.0 cm)
2-9/16"
(6.5 cm)
1-3/16"
(3.0 cm)
1-3/16"
(3.0 cm)
17-3/4"
(45.1 cm)
Recommended vent system length
Use 3 1/4" x 10" (8.3 cm x 25 cm) vent with maximum length of
26 feet (8 m) for vent system. For best performance, use no more
than three 90° elbows. To calculate the length of system you need,
add the equivalent feet (meters) for each vent piece used in the
system. See the following example.
wall
cap
3-1/4" x 10"
(8.3 cm x 25 cm)
90° elbow
Maximum length
1 — 90° elbow
9 ft. (2.8 m) straight
1 — wall cap
Length of 3-1/4" x 10"
(8.3 cm x 25 cm)
system
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
9-15/16"
(25.2 cm)
1-9/16"
(4.0 cm)
7-3/4"
(19.6 cm)
1-13/16"
(4.6 cm)
9-27/32"
(25.0 cm)
30" (76.2 cm)
36" (91.4 cm)
Roof-vented model shown.
3-1/4" x 10" (8.3 cm x 25 cm)
vent system
6 ft. (1.8 m)
3 ft.
(0.93 m)
= 26 ft.
= 5 ft. (1.5 m)
= 9 ft. (2.8 m)
= 0 ft.
= 14 ft. (4.3 m)
2-11/32"
(6.0 cm)
1-3/4"
(4.4 cm)
Do not
use these
knockouts
wall
cap
(8 m)
(0 m)
Ref. 8284977
08-20-02

Advertisement

loading

This manual is also suitable for:

Khtu160k