Plan the exhaust vent
installation
Typical installations exhaust from the rear
of the dryer.
exhaust
outlet
The exhaust outlet is located at the
center of the rear of the dryer.
Route the vent
The exhaust vent can be routed up,
down, left, right or straight out the
back of the dryer. See "Recessed
area/closet installation" section, Page 4,
for space requirements.
8
exhaust air
flow
acceptable
better
Select the route that will provide the
straightest and most direct path
outdoors. Plan the installation to use
the fewest number of elbows and
turns. Avoid making 90° turns.
When using elbows or making
turns, allow as much room as
possible. Bend vent gradually to avoid
kinking.
Determine vent length
Preferred —
4"
When you have a 4' hood
Maximum length of 4" diameter
metal vent
Number of
Rigid
90° elbows
0
64 feet
1
54 feet
2
44 feet
3
35 feet
4
27 feet
Acceptable —
When you have a 2-1/2' hood
Maximum length of 4" diameter
metal vent
Number of
Rigid
90° elbows
0
58 feet
1
48 feet
2
38 feet
3
29 feet
4
21 feet
The maximum length of the exhaust
system depends upon:
• the type of vent (rigid or flexible
metal).
• the number of elbows used.
1. See the exhaust vent length chart
that matches your type hood for the
maximum vent lengths you can use.
Do not use vent runs longer
than specified in exhaust vent
length charts.
Exhaust systems longer than
specified will:
— accumulate lint creating a
potential fire hazard.
— shorten the life of the dryer.
— reduce performance, resulting in
longer drying times and
increased energy usage.
2. Determine the number of elbows
you will need.
3. In the column listing the type of
metal vent you are using (rigid or
4"
flexible), find the maximum length of
metal vent on the same line as the
number of elbows.
4. Determine the number of 4-inch
diameter vent clamps required.
The maximum length using a 2" x
Flexible
6" rectangular vent with 2 elbows
(fully extended)
36 feet
and a 2-1/2" exhaust hood is 8 feet.
31 feet
For exhaust systems not covered
27 feet
by exhaust vent length charts (such
25 feet
as multiple unit hookups, plenums,
23 feet
and power-assist fans), see Service
Manual, Part No. 603197. (To
purchase the Service Manual, see
your Use and Care Guide for a
toll-free telephone number.)
2-1/2"
Flexible
(fully extended)
28 feet
23 feet
19 feet
17 feet
15 feet