Frigidaire FHWC3025 Installation, Use & Care
Hide thumbs Also See for FHWC3025:

Advertisement

USA 1-800-944-9044
www.frigidaire.com
Canada 1-800-265-8352
www.frigidaire.ca
LI30KC / 316902495
May/13

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FHWC3025

  • Page 1 USA 1-800-944-9044 Canada 1-800-265-8352 www.frigidaire.com www.frigidaire.ca LI30KC / 316902495 May/13...
  • Page 2: Table Of Contents

    Install Range Hood (Ducted version) ..... 10 Make Electrical Connection ........12 Installing Range Hood (Recirculating version) ..10 Visit the Frigidaire web site at www.frigidaire.com Range Hood Use ..........13 Before you call for service, there are a few things you can Range Hood Care ..........
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Read all instructions before using this appliance. Save these instructions for future references WARNING Approved for residential appliances TO REDUCE THE RISK OF FIRE, ELECTRIC For residential use only SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Do not attempt to install or operate your appliance until Use this unit only in the manner intended by the you have read the safety precautions in this manual.
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS WARNING WARNING To Reduce The Risk Of Fire Or Electric Shock, Do TO REDUCE THE RISK OF INJURY TO PERSONS, Not Use This Hood With Any External Solid State IN THE EVENT OF A RANGE TOP GREASE FIRE, Speed Control Device.
  • Page 5: List Of Materials

    LIST OF MATERIALS LIST OF MATERIALS ELECTRICAL REQUIREMENTS Parts included in your hood Observe all governing codes and ordinances. 4 - 0.45 x 1.3 cm mounting screws Ensure that the electrical installation is adequate and in • 3¼” x 10” (8.3 x 25.4 cm) rectangular metal vent conformance with National Electrical Code, ANSI/NFPA • system. 70 (latest edition), or CSA Standards C22.1-94, Canadian NOTE: An optional 7”...
  • Page 6: Location Requirements

    D. 36” (91.4 cm) base cabinet height PRODUCT DIMENSIONS hood model Dim A Dim B DIM B ” 30” (76.2 cm) ” (16.7 cm) FHWC3025 (2.2cm) 30” models ”(1.4cm) 10” (25.4cm 36” (91.44 cm) 9½” (24.3 cm) FHWC3625 9½” (24cm) 36”...
  • Page 7: Venting Requirements

    VENTING REQUIREMENTS Vent system must terminate to the outdoors. • Roof Venting Wall Venting Do not terminate the vent system into an attic or other • enclosed area. Do not use a 4” (10.2 cm) laundry-type wall cap. • Use a 3¼” x 10” (8.3 x 25.4 cm) rectangular metal •...
  • Page 8: Prepare The Location

    VENTING REQUIREMENTS PREPARE THE LOCATION ¼” x 10” (8.3 cm x 25.4 cm) Vent System Vent Piece NOTE 3¼” x 10” (8.3 cm x 25.4 cm) 5.0 ft 90° elbow (1.5 m) Before making cutouts, make sure there is proper clearance within the ceiling or wall. 3¼” x 10” (8.3 cm x 25.4 cm) 12.0 ft flat elbow (3.7 m) Disconnect power.
  • Page 9 PREPARE THE LOCATION To wire through top: Style 2 - Cut Openings for 3¼” x 10” (8.3 cm x Mark a line distance (A) from the right of the .4 cm) Rectangular Vent System centerline on the underside of the cabinet. Mark the point on this line that is ⁄...
  • Page 10: Install Range Hood (Ducted Version)

    PREPARE THE LOCATION Style 3 - Cut Openings for 3¼” x 10” (8.3 x 25.4 Install Vent System cm) Rectangular Vent Transition to Round Vent Install vent through the vent opening in upper cabinet or wall. Complete venting system according to the Roof Venting selected venting method.
  • Page 11: Installing The Hood

    INSTALLING THE HOOD Use ¹⁄ ” (3 mm) drill bit and drill 4 pilot holes as shown. Power Supply Cable Installation NOTE: Make the drill holes on the thin area of the slot. For direct wire installations, run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances.
  • Page 12: Make Electrical Connection

    INSTALLING THE HOOD MAKE ELECTRICAL CONNECTION INSTALL RANGE HOOD (Recirculating version) WARNING Lift the range hood up under cabinet and determine Electrical Shock Hazard final location by centering beneath cabinet. Mark on Disconnect power before servicing. the underside of cabinet the location of the 4 keyhole Replace all parts and panels before operating. mounting slots on the range hood (See slots Failure to do so can result in death or electrical shock.
  • Page 13: Range Hood Use

    RANGE HOOD USE RANGE HOOD USE Remove the power supply knockout from the top or rear of the vent hood (depending on the incoming The range hood is designed to remove smoke, cooking location of your home power supply cable) and vapors and odors from the cooktop area.
  • Page 14: Range Hood Care

    RANGE HOOD CARE Cleaning Replace screw in the filter WARNING retainer. To clean grease filter, soak To Reduce The Risk Of Fire Or Electrical shock the filters in hot water using disconnect from power supply before cleaning. a mild detergent. Rinse well and shake to dry. Or place IMPORTANT in upper rack of dishwasher A.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Problem Possible Causes Solutions After installation, 1. The power line and the cable locking 1. Check the power connection with the unit is the unit doesn’t connector is not connecting properly. connected properly. work. 2. The wires from the switches are disconnected 2.
  • Page 16: Warranty Information

    Warranty Your appliance is covered by a one year limited warranty. For one year from your original date of purchase, Electrolux will repair or replace any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used, and maintained in accordance with the provided instructions.
  • Page 17 printed in Mexico...

This manual is also suitable for:

Fhwc3625

Table of Contents