Hitachi N 3804AB3 Instruction And Safety Manual page 14

Hide thumbs Also See for N 3804AB3:
Table of Contents

Advertisement

Otherwise, it will be set to CONTACT
ACTUATION MECHANISM.)
2 Position the staple outlet on the workpiece
with finger off the trigger.
3 Depress the push lever firmly until it is
completely depressed.
4 Pull the trigger to drive a staple.
5 Remove finger from the trigger.
To continue stapling in a separate location, move
the stapler along the workpiece, repeating steps
2 - 5 as required.
1 Upward position
Push lever
(2) Continuous operation (Push lever fire)
Using CONTACT ACTUATION MECHANISM
To avoid double firing or accidental
firing due to recoil.
1)
Do not press the stapler against the
workpiece with excessive force.
2)
Separate the stapler from the
workpiece as it recoils after
stapling.
1 Set the switching device to the downward
position (to set to CONTACT ACTUATION
MECHANISM).
(Set the switching device to the downward
position completely as shown in the diagram.
Otherwise, it will not operate properly.)
14
Switching device
3
4
Trigger
WARNING
2 Pull the trigger with the Stapler off the
workpiece.
3 Depress the push lever against the workpiece
to drive a staple.
4 Move the Stapler along the workpiece with a
bouncing motion.
Each depression of the push lever will drive
a staple.
As soon as the desired number of staples have
been driven, remove finger from the trigger.
1 Downward position
4
Push lever
Previously pull
the trigger
Keep your finger off the trigger except
during fastening operation, because
serious injury could result if the push
lever accidentally contacts you or others
in work area.
Keep hands and body away from the
discharge area. The Stapler with contact
trip mechanism may bounce from the
recoil of driving a fastener and
unwanted subsequent fastener may be
driven, possibly causing injury.
Some types of loaded staples can spark
out of the muzzle during a staple driving
operation. Exercise caution!
THE FULL SEQUENTIAL ACTUATION MECHANISM
(SEQUENTIAL TRIP MECHANISM) is for use where
precision fastener placement is desired and must be
operated in accordance with the following "Method of
Operation".
Switching device
2
WARNING

Hide quick links:

Advertisement

Table of Contents
loading