Electrical; Power Supply Locations; Gas Supply; Electrical Supply - GE PGP989 Owner's Manual And Installation Instructions

Gas downdraft
Table of Contents

Advertisement

Available languages

Available languages

GAS SuPPly:

These cooktops are designed to operate on
natural gas at 4" of water column pressure or
on LP gas at 10" of water column pressure .
• These cooktops are shipped from the factory
set for natural gas . If you decide to use this
cooktop with LP gas, conversion adjustments
must be made by a service technician or
other qualified person .
• The pressure regulator must be connected in
series with the manifold of the cooktop and must
remain in series with the supply line regardless
of type of gas being used .
For proper operation, the maximum inlet pressure
to the regulator must be no more than 10" water
column pressure for natural gas and 14" water
column pressure for LP gas .
• When checking the regulator, the inlet pressure
must be at least 1" greater than the regulator
output setting . If the regulator is set for 4" of
water column pressure, the inlet pressure must
be at least 5" . If the regulator is set for 10" of
water column pressure, the inlet pressure must
be at least 11" . For ease of installation, and if local
codes permit, the gas supply line into the cooktop
should be 1/2" or 3/4" ID flexible metal appliance
connector, three to five feet long .
notE: Purchase a new flexible line . Do not uSE
An olD PrEVIouSly uSED lInE.
• Make gas connection through rear wall, or on
cabinet floor at rear, as illustrated .
Installation Instructions

PoWEr SuPPly loCAtIonS

23

ElECtrICAl SuPPly:

29
"
1
2
C L
Gas pipe
location
4" (to clear toe kick area)
The built-in gas downdraft cooktop features
pilotless electric ignition for energy savings and
reliability . It operates on a 120-volt, 60-Hz power
supply . A separate circuit, protected by a 15-amp
time-delay fuse or circuit breaker, is required .
• A properly grounded 3-prong receptacle should
be located within reach of cooktop's four foot
power cord .
ImPortAnt: (Please read carefully.) For
PErSonAl SAFEty, tHIS APPlIAnCE muSt BE
ProPErly GrounDED.
The power cord of this appliance is
equipped with a three-prong (grounding) plug
which mates with a standard three-prong
grounding wall receptacle to minimize the
possibility of electric shock hazard from this
appliance . The customer should have the wall
receptacle and circuit checked by a qualified
electrician to make sure the receptacle is properly
grounded and has correct polarity .
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle .
Do not, under Any Circumstances, Cut or
remove the third (ground) Prong From the
Power Cord.
Do not use an extension cord .
2"

Electrical

min
outlet 12"
3"
above cabinet
min
floor (mount
on side or
back cabinet
wall 2" min .
from
centerline)

Advertisement

Chapters

Table of Contents
loading

Table of Contents