ASSEMBLY TIPS + TEST CRITERIA AND CONTROLS + POSSIBLE COMPLAINTS
ASSEMBLY TIPS
- Adjusting knob (11) ;
Before assembling the adjusting
knob (11), set the cam of the
adjusting unit 10 to the indicated
position.
- Adjusting the hand-strap
1
1
L
3
M
S
POSSIBLE COMPLAINTS
Status
1. Switch in "OFF" position
2. Switch set to level 1
3. Switch set to level 1-5 and
product not placed on the skin
4. Switch set to level 1-5 and
product properly placed
To check, if the product functions properly.
- Remove sieve (13).
- Set the switch to level 1. ⇒ The rollers should rotate continuously and the LED doesn't burn.
- Cover the suction opening with the thumb. ⇒ The LED lights up.
- Press the vacuum stop-buttons. ⇒ The LED goes out and the rollers stop rotating.
3
2
1
5
0
2
2
4
Failure
Pump functions
Pump doesn't function
LED burns
Product doesn't function
- Spring: Before replacing
4
N.B.
- To avoid dust from getting into the pump, the suction
opening has been closed with a plastic cap. Remove the
plastic cap before assembling.
- After the product has been repaired, it should
function properly and has to meet the safety
requirements as laid down and offi cially established
at this moment.
TEST CRITERIA AND CONTROLS
Total product
Adapter: Primary voltage
Secondary voltage
Pump
Motor rollers
Cause
ON/OFF switch defective
Adapter defective
ON/OFF switch defective
Internal wiring broken
Defective PCB
Motor pump defective
Filter is clogged
Electronic switch defective
Defective PCB
Electronic switch defective
Defective PCB
Sleeves got loose
Vacuum stop defective
Gearing motor defective
Pump clogged - fi lter missing
Internal wiring broken
2 mm
Voltage
Ampere
13.0 V
380 mA ± 10 %
220-240 V
13.0 V
400 mA
if < 12.5 V adapter is defective
13.0 V
180 mA ± 10%
13.0 V
180 mA ± 10 %