Installing the appliance, figures 5/6

Connect the appliance to the mains to check its working.
Voltage, see specifications plate.
Connect only according to the connection drawing (figure 6).
1. Brown
2. Blue
3. Yellow and green
Changing the intensity of the 13 / 16 / 20 Amp
connection current, figure 7
Before using the hob for the first time, the intensity of the hob
connection must be tested.
Follow the steps below to change the current of the hob:
Turn on the hob with the main switch. Do not place any pans
1.
on the hotplates
Within the following 60 seconds, adjust all hotplates to the
2.
desired power level according to the required connection
current (see table).
Power level
Connection current in amperes
20 A
16 A
ƒ
13 A
Turn off all the hotplates in sequence, starting from the lower
3.
right and continuing counter-clockwise.
The selected connection current is indicated in the display of
4.
the right-hand lateral hotplates.
Turn off the hob with the main switch.
5.
The selected connection current will have been properly saved.

Uninstalling the appliance

Disconnect the appliance from the mains.
Push the hob upwards from below to remove it.
Caution!
Damage to the appliance! Do not try to remove the appliance
by prying it out from above.