9. Troubleshooting
Wiring diagram for repair
Symptom
Procedure
Inspection
Cause
Countermeasure
A. No indication ap
1) Remove the power cord
Microcomputer
Normalized
pears on LD1
from the socket. Wait 10
went
out
of
control
due to
when the power
seconds and then turn
external noise.
plug
is
con-
the power on again.
YES
netted
to the
power outlet
2) Measure the voltage
Poor
connec-
Repair wiring
NO
tionofCN101
between @ and @ to
check ifAC 230V is sup
Poor
connec-
Repair wiring
plied
to the
power
tion of connec-
board.
YES
tor lead wire.
Thermal
fuse
Replace ther-
failure
mal fuse
3) Measure
voltage
to
Power
board
Replace power
check
if the
power
board
board
is in normal
Fuse 315mA
Replace the
condition.
blowout
fuse 315mA
@-(@
Approx. DC5V
4) Measure
voltage
to
NO
Poor connec-
Repair
wiring
check
if the control
tion of 6-core
board
is in normal
parallel wire
condition.
@-@
approx. DC 5V
Control
board
Replace control
board
3. Operation
key
1) Remove
the power
Microcomputer
Normalized
input is not ac-
cord from the socket.
Start
went
out
of
Wait 10 seconds and
control
due to
cepted.
then turn the power
external noise.
on again.
YES
NO
* Control
board
Replace control
failure
board