Sharp LC-13B2U Service Manual
Sharp LC-13B2U Service Manual

Sharp LC-13B2U Service Manual

Hide thumbs Also See for LC-13B2U:

Advertisement

Quick Links

In the interests of user-safety (Required by safety regulations in some countries) the set should be restored
to its original condition and only parts identical to those specified should be used.
PRECAUTION.................................................... 2
» SPECIFICATIONS ............................................. 4
» OPERATION MANUAL ...................................... 5
» DIMENSIONS .................................................... 9
» REMOVING OF MAJOR PARTS ..................... 10
EACH SECTION .............................................. 13
» TROUBLE SHOOTING TABLE ........................ 16
» CHASSIS LAYOUT .......................................... 20
» BLOCK DIAGRAM ........................................... 22
Ë MAIN UNIT ................................................ 26
SHARP CORPORATION
SERVICE MANUAL
LCD COLOR TELEVISION
LC-13B2U
MODEL
CONTENTS
Page
Ë TERMINAL UNIT ....................................... 34
Ë JACK UNIT ................................................ 38
Ë ELECTRICAL PARTS ................................ 43
Ë MAIN UNIT ................................................ 43
Ë TERMINAL UNIT ....................................... 46
Ë OPERATION UNIT ..................................... 48
Ë JACK UNIT ................................................ 49
Ë R/C RECEIVER UNIT ................................ 49
Ë CABINET PARTS LOCATION .............. 49, 52
Ë CABINET AND MECHANICAL PARTS ..... 50
Ë ACCESSORIES PARTS ............................ 52
Ë PACKING PARTS ....................................... 52
» PACKING OF THE SET ................................... 53
This document has been published to be used for
after sales service only.
The contents are subject to change without notice.
1
LC-13B2U
S61U5LC-13B2U
Page

Advertisement

Table of Contents
loading

Summary of Contents for Sharp LC-13B2U

  • Page 1: Table Of Contents

    LC-13B2U SERVICE MANUAL S61U5LC-13B2U LCD COLOR TELEVISION LC-13B2U MODEL In the interests of user-safety (Required by safety regulations in some countries) the set should be restored to its original condition and only parts identical to those specified should be used.
  • Page 2: Important Service Safety Precaution

    LC-13B2U IMPORTANT SERVICE SAFETY PRECAUTION Ë Service work should be perfomed only by qualified service technicians who are thoroughly familiar with all safety checks and the servicing guidelines which follow: • Use an AC voltmeter having with 5000 ohm per volt, or...
  • Page 3 LC-13B2U PRECAUTIONS A PRENDRE LORS DE LA REPARATION Ë Ne peut effectuer la réparation qu' un technicien spécialisé qui s'est parfaitement accoutumé à toute vérification de sécurité et aux conseils suivants. • Utiliser un voltmètre CA d'une sensibilité d'au moins AVERTISSEMENT 5000Ω/V pour mesurer la chute de tension en travers...
  • Page 4: Specifications

    LC-13B2U Specifications Items LC-13B2U Model LCD panel 13” TFT LCD Number of pixels 921,600 pixels VGA Video color systems N358, N443, PAL, PAL-M, PAL-N, SECAM, PAL-60 Destination USA/Latin A/Twn TV Standard (CCIR) NTSC/PAL-M/PAL-N TV function TV Tuning System PLL 181 ch.
  • Page 5: Operation Manual

    LC-13B2U Operation Manual...
  • Page 6 LC-13B2U...
  • Page 7 LC-13B2U...
  • Page 8 LC-13B2U...
  • Page 9: Dimensions

    LC-13B2U Dimensions 16.9/429 10.4/265 10.6/270 3.7/92.7 2.2/55 ANT. AV-IN1 VIDEO AV-IN2/OUT VIDEO AUDIO AUDIO S-VIDEO COMPONENT AUDIO H E A D PHONE POWER INPUT DC12V 2.2/55.3 7.0/177.8 (Unit: inch/mm)
  • Page 10: Removing Of Major Parts

    LC-13B2U REMOVING OF MAJOR PARTS 1. Remove the back cover. 2. Remove the table stand fixing screws (4 pcs.). 3. Remove the cabinet B fixing screws (9 pcs.) and detach the cabinet. 4. Release the wire holders at 2 locations and peel off the tape.
  • Page 11 LC-13B2U 6. Remove the terminal PWB fixing screws (4 pcs.). 7. Remove the jack PWB fixing screws (2 pcs.). 8. Remove the main PWB fixing screws (2 pcs.). 9. Remove the R/C receiver PWB fixing screws (2 pcs.). 10. Remove the operation PWB fixing screws (2pcs.).
  • Page 12 LC-13B2U » Precautions in handling the LCD panels 1. Work in a clean room (with humidities below 50%). 2. Be sure to wear an anti-static armband. 3. Handle the panels on an electroconductive mat. 4. Be careful not to fall, shake and shock the panels.
  • Page 13: Adjusting Procedure Of Each Section

    LC-13B2U ADJUSTING PROCEDURE OF EACH SECTION The best adjustment is made before shipping. If any position deviation is found or after part replace is performed, adjust as follows. 1. Preparation for Adjustments (1)Use the exclusive-use AC adapter or stable DC power supply.
  • Page 14 LC-13B2U 3. Cancel of special mode Turn off the main unit power. 4. Adjustments Adjustment Adjusting conditions Adjusting method B+ Adjustment 1. Connect the DC voltmeter to 1. Adjust the "B+ Adj" value to (R3760) pin 38 of SC3403. 5.0 ±0.02V with R3760.
  • Page 15 LC-13B2U 5. Shipping setting list Channel ............................... 2ch Air/Cable ............................. Air Skip Data_CATV ..........................All Skip Skip Data_AIR ............................ All Not Skip Volume ..............................20 Picture ..............................30 Tint ..............................0 Color ..............................0 Black Level ............................0 SHARPNESS ............................0 RED-BLUE ............................
  • Page 16: Trouble Shooting Table

    LC-13B2U TROUBLE SHOOTING TABLE No Power (Power LED indicator still in red) Go to the adjustment process mode. +B-ADJ MODEL INCH SIZE SYSTEM AUTO NTSC PWM FREQ PAL PWM FREQ NTSC PWM DUTY PAL PWM DUTY TV GAIN ERROR NO RESET...
  • Page 17 LC-13B2U TROUBLE SHOOTING TABLE (Continued)
  • Page 18 LC-13B2U TROUBLE SHOOTING TABLE (Continued)
  • Page 19 LC-13B2U TROUBLE SHOOTING TABLE (Continued)
  • Page 20: Chassis Layout

    LC-13B2U CHASSIS LAYOUT MAIN Unit (Side A) JACK Unit OPERATION Unit R/C RECEIVER Unit TERMINAL Unit MAIN Unit (Side B)
  • Page 21: Block Diagram

    LC-13B2U BLOCK DIAGRAM TERMINAL UNIIT JACK UNIT L1, R1 TV-V S-VIDEO TUNER SY, SC TU3201 INPUT INVERTER LAMPS Q5701, Q5702 V2/VO T5701, T5702 COLD AUDIO VIDEO INPUT IN/OUT IN/OUT OUTPUT SWITCH SWITCH IC3501 Q3501-Q3505 Q3500 LAMP CHECK MAIN UNIT Y, PB, PR...
  • Page 22: Description Of Schematic Diagram

    LC-13B2U DESCRIPTION OF SCHEMATIC DIAGRAM VOLTAGE MEASUREMENT CONDITION: CAUTION: 1. Voltages at test points are measured at the This circuit diagram is original one, therefore there may be a supply voltage of AC 120V. Signals are fed by a slight difference from yours.
  • Page 23: Schematic Diagramë Operation And R/C Receiver Unit

    LC-13B2U SCHEMATIC DIAGRAM Ë OPERATION and R/C RECEIVER Unit OPERATION R/C RECEIVER...
  • Page 24: Ë Main Unit

    LC-13B2U Ë MAIN Unit-1/4...
  • Page 25 LC-13B2U Ë MAIN Unit-2/4...
  • Page 26 LC-13B2U Ë MAIN Unit-3/4...
  • Page 27 LC-13B2U Ë MAIN Unit-4/4...
  • Page 28: Ë Terminal Unit

    LC-13B2U Ë TERMINAL Unit-1/2...
  • Page 29 LC-13B2U Ë TERMINAL Unit-2/2...
  • Page 30: Ë Jack Unit

    LC-13B2U Ë JACK Unit...
  • Page 31: Printed Wiring Board Assemblies

    LC-13B2U PRINTED WIRING BOARD ASSEMBLIES R/C Receiver Unit (Component Side) Operation Unit (Component Side) Jack Unit (Component Side)
  • Page 32 LC-13B2U Main Unit (Side-A)
  • Page 33 LC-13B2U Main Unit (Side-B)
  • Page 34 LC-13B2U Terminal Unit (Component Side)
  • Page 35: Parts List

    4. DESCRIPTION in USA: Contact your nearest SHARP Parts Distributor to order. in CANADA: Contact SHARP Electronics of Conada Limited For location of SHARP Parts Distributor, Please call Toll- Phone (416) 890-2100 Free; 1-800-BE-SHARP MARK: SPARE PARTS-DELIVERY SECTION MARQUE: SECTION LIVRAISON DES PIECES DE RECHANGE Ref.
  • Page 36 LC-13B2U Ref. No. Part No. Description Code Ref. No. Part No. Description Code DUNTKA562DE01 C1111 VCKYCY1EF104Z J 0.1 Ceramic C1112 VCKYCY1EF104Z J 0.1 Ceramic MAIN UNIT (Continued) C1113 VCKYCY1EF104Z J 0.1 Ceramic C1114 VCKYCY1EF104Z J 0.1 Ceramic L1204 VP-1M220J2R9N J Peaking 22µH C1115 VCKYCY1EF104Z J 0.1...
  • Page 37 LC-13B2U Ref. No. Part No. Description Code Ref. No. Part No. Description Code DUNTKA562DE01 R1204 VRS-CB1JF220J J 22 1/16W Metal Oxide R1205 VRS-CA1JF220J J 22 1/16W Metal Oxide MAIN UNIT (Continued) R1206 VRS-CB1JF220J J 22 1/16W Metal Oxide R1207 VRS-CA1JF220J...
  • Page 38 LC-13B2U Ref. No. Part No. Description Code Ref. No. Part No. Description Code DUNTKA563DE01 TRANSFORMER T3701 RTRNZ0800CEZZY J Transformer TERMINAL UNIT CONTROL TUNER R3760 RVR-M8026TAZZ J 1k (B) +B Adj. NOTE: THE PARTS HERE SHOWN ARE SUPPLIED AS AN CAPACITORS ASSEMBLY BUT NOT INDEPENDENTLY.
  • Page 39 LC-13B2U Ref. No. Part No. Description Code Ref. No. Part No. Description Code DUNTKA563DE01 R3320 VRS-CY1JF393F J 39k 1/16W Metal Oxide R3321 VRS-CY1JF433F J 43k 1/16W Metal Oxide TERMINAL UNIT (Continued) R3322 VRS-CY1JF183J J 18k 1/16W Metal Oxide R3323 VRS-CY1JF433F...
  • Page 40 LC-13B2U Ref. No. Part No. Description Code Ref. No. Part No. Description Code DUNTKA563DE01 MISCELLANEOUS PARTS å F3701 QFS-B2021GEZZ J Fuse, 2A/125V TERMINAL UNIT (Continued) å F3703 QFS-B2521GEZZ J Fuse, 2.5A/125V FB3301 RBLN-0006TAZZ J Ferrite Bead R3529 VRS-CY1JF821J J 820 1/16W Metal Oxide...
  • Page 41: Ë Jack Unit

    LC-13B2U Ref. No. Part No. Description Code Ref. No. Part No. Description Code DUNTKA565DE01 CABINET PARTS LOCATION JACK UNIT CCABA2429CE01 J Front Cabinet Ass’y TRANSISTORS Not Available – Front Cabinet — Q5701 VSFZT1053A/-1 J FZT1053A GCOVA2004CEZZ J Cover, R/C Receiver/LED...
  • Page 42 LC-13B2U CABINET AND MECHANICAL PARTS 1-11 1-10 OPERATION Unit 1-13 1-12 1-12 1-13 1-11 1-13 1-12 JACK Unit 1-13 1-12 MAIN Unit R/C RECEIVER Unit TERMINAL Unit...
  • Page 43 LC-13B2U 3-10 3-12 3-14 3-15 3-11 3-12 3-12 3-15 3-12 3-13...
  • Page 44: Ë Cabinet Parts Location

    LC-13B2U Ref. No. Part No. Description Code Ref. No. Part No. Description Code CABINET PARTS LOCATION ACCESSORIES PARTS (Continued) XBBSF30P05000 J Screw, x1 LHLDW0109CESA J Cable Clamp, x2 å XBPSD30P03000 J Screw, x3 QACCD3097CEPA J AC Cord XBPSD30P10JS0 J Screw, x4 (Earth)
  • Page 45: Packing Of The Set

    LC-13B2U PACKING OF THE SET Operation Manual Cable Clamp (2 pcs.) Dry Battery (2 pcs.) AC Adapter AC Cord Antenna Cable Wireless Remote Control Buffer Material (Top) Polyethylene Bag Buffer Material (Bottom) Packing Case Not Replacement Item...
  • Page 46 LC-13B2U COPYRIGHT © 2001 BY SHARP CORPORATION ALL RIGHTS RESERVED. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher.

Table of Contents