GE WCRE6270K Technical Service Manual page 22

Profile washers with infusor wash systm
Hide thumbs Also See for WCRE6270K:
Table of Contents

Advertisement

Fill Levels and Testing
The minimum fi ll volume on the setting of SMALL
is 10 gallons. The water level will measure
approximately 6" above the bottom of the basket or
just above the fourth row of holes.*
On the SUPER setting the fi ll volume is 15.5 gallons.
The water level will measure approximately 9"
above the bottom of the basket or just above the
eighth row of holes.*
SUPER setting is the only setting where the water
will come up to the top of the Infusor.
Minimum Fill Level
* Measured water levels are approximate and can
vary +/- 1".
A quick check of pressure switch operation is to
monitor the mode shifter. When the lower pressure
switch opens, the mode shifter disengages the 15
rpm fi ll/spin and the shifter resets for wash agitate.
It will slow agitate at 15 rpm until the fi ll time is
reached.
This opening of the lower switch contact occurs at
approximately 4 inches water depth or just above
the bottom section of the Infusor.
Due to fi ll timing, water pressure is critical. These
units will not fi ll to proper levels with water pressure
under 20 psi or clogged valve inlet screens.
To remove the precise fi ll pressure switch:
1.
Remove the cover/lid. (See
2.
Disconnect the 2 wire harnesses and remove
the pressure hose attached to the pressure
switch.
3.
Push the disconnected end of the pressure hose
through the entry hole in the back frame.
Pressure
Hose
4. Remove the four 1/4-in. hex-head screws that
attach the back frame to the cabinet.
5. Turn the back frame over, compress the side
tabs, and remove the precise fi ll pressure switch.
Side Tab
– 22 –
Cover/Lid Assembly
Disconnect
Disconnect
Entry Hole
Side Tab
.)