(19) The spring plate can be taken out by removing its fitting screw.
(20) The joint ass'y, the holder (base) and tube can be dismounted by removing the holder (base) fitting
ring,
Precautions
for Reassembly
(1)
When mounting the power cord, the cord bushing should be attached to the cord holder so that the
dimensions between the bushing and the top of the terminal is approx. 25 mm. (Fig. 6)
(2) Wiring should be made as shown in the specified wiring diagram. (Fig. 6)
Power PCB z Control PCB
Black with socket
qL
Power PCB
\
\
Motor'= Power PCB
Blue and Yellow with socket
,~flfl
~~
]yea~h~;~B
'r
5=='UI
White with socket
.@.!.wL
--
(Fig. 6)