Yamaha DRX-2 Service Manual page 75

Hide thumbs Also See for DRX-2:
Table of Contents

Advertisement

Nucleus Name
DS_SYS_DisplayFatalGet
Nucleus Number
1225
Description
Get the display-fatal flag of the recorder
Technical
-
Issue the command to get the status of the display-fatal functionality to the analog board
-
Wait for the result and return this to the user
Execution Time
Less than 1 second.
User Input
None
Error
Number
122500
122501
122502
122503
122504
Example
DS:> 1225
122500:
Test OK @
Nucleus Name
DS_SYS_SettingsSet
Nucleus Number
1226
Description
Programs the digital board settings into the boot EEPROM on the digital board.
Technical
-
Evaluate user input.
-
Setup IIC-bus.
-
Writedata to boot EEPROM.
-
Update checksum.
Execution Time
1 second
User Input
A large hexadecimal value that represents the digital board settings obtained from the
DbString.exe program or from a reference set.
Error
Number
122600
122601
122602
Example
DS:> 1226 646961677473746201010200010101010101000020080000
122600:
Test OK @
Description
Getting the display-fatal flag succeeded
Getting the display-fatal flag failed
The returned errorcode from the analog board is unknown:
No DS errCode known for analog board error:
There was no response from the analog board.
Description
The settings were successfully programmed.
User input is invalid.
IIC access failed.
DRX-2
75

Advertisement

Table of Contents
loading

Table of Contents