Specifications

Specifications are valid over the given bandpass and operating temperature range of −40°F to
+140°F (−40°C to +60°C). Specifications are stated typical unless otherwise noted, and are
subject to change. Refer to the Motorola CHS web site or contact your account representative for
the latest specifications.

Model BT100

Specification
Passband
Gain
Full
Operational
Flatness
52 through 1003 MHz
Level control, automatic
Gain control
Performance - reference frequency
(MHz)
At typical output (dBmV)
Channels
Crossmod (worst case)
CTB (worst case)
CSO (worst case)
Noise figure
At 52 MHz
At 1003 MHz
Interstage equalizer, BDR-1G
Hum modulation
Return loss, input/output
Test points, input/output
Housing dimensions
Weight
Forward Amplifier
52 through 1003 MHz
46 dB (with SFE-*-*)
42 dB (with SFE-*-* and slope reserves)
±0.70 dB maximum
Bode board using ADU/QADU/TDU
Fixed pads, JXP-∗B
1003/550/52
45/44/37
79 analog/320 MHz
digital (suppressed by
6 dB)
–66 dB
–75 dB
–71 dB
10 dB (with SFE-1)
10 dB (with SFE-1)
14 ±1 dB
–70 dB
16 dB at operational level
20 ±1.0 dB
21.6 L × 10.6 W× 7.7 D inches (54.9 × 26.9 × 19.6 cm)
27 pounds (12.25 kg)