Download Print this page

Kenwood MDX-G3 Service Manual page 11

Hide thumbs Also See for MDX-G3:

Advertisement

QQ
3 7 63 1515 0
CD player check
No.
ITEM
SETTING
Step 1~2 are in TEST MODE
TEST MODE : While pressing the [CD PLAY/PAUSE] key, turn power on.
LASER
1
POWER
Test disc
LASER
2
Type 4
CURRENT
Note:
Type 4disc :SONY YEDS-18 Test Disc or equivalent. (KTD-02)
LPF : Around 47kΩ + 390pF or so.
(a) Laser Power
TE
L 13942296513
Pickup
www
.
ADJUSTMENT
INPUT
OUTPUT
SETTING
Set the sensor sec-
tion of the optical
power meter on the
pickup lens.
Connect the DC
voltmeter to
CN25(#1 and #2) in
X09
0.05~0.15 mW
Optical power meter
x
ao
y
i
8
PLAYER
ALIGNMENT
SETTING
POINT
Short circuit
OPEN/CLOSE SW.
Press the "PLAY" key
to check that the dis-
play is "03".
Press the "PLAY" key
to check that the dis-
play is "03" or "05"
(d)
RF signal: AC coupled
Q Q
3
6 7
1 3
RF signal in test mode (PLAY).
Perform the tangential and focusing offset are focused
into one point on the display. The crossing points above
and below the center shall also be looked clearly.
u163
.
MDX-G3
2 9
9 4
2 8
ALIGN FOR
On the power from
0.05 to 0.15mw. when
the diffraction grating
is correctly aligned
with the RF level of
0.8Vp-p or more
220mV to 550mV
1 5
0 5
8
2 9
9 4
m
co
9 9
FIG.
(a)
2 8
9 9
11