KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW Note: Because CONTENTS 4 is the extract from the Operating Instructions of this model, it is subject to change without notice. You can download and refer to the original Operating Instructions on TSN Server for further information.
Page 3
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 26.2. Handset 30 CIRCUIT BOARD (BASE UNIT) 26.3. Accessories and Packing Materials 30.1. Component View 27 FOR SCHEMATIC DIAGRAM 30.2. Flow Solder Side View 27.1. Base Unit (SCHEMATIC DIAGRAM (BASE UNIT)) 31 CIRCUIT BOARD (HANDSET) 27.2.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 1 ABOUT LEAD FREE SOLDER (PbF: Pb free) Note: In the information below, Pb, the symbol for lead in the periodic table of elements, will refer to standard solder or solder that contains lead.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 5 DISASSEMBLY INSTRUCTIONS Shown in Fig.- To Remove Remove Cabinet Cover Screws (2.6 × 12)....... (A) × 4 Main P.C. Board Main P.C. Board...
Page 11
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW Shown in Fig.- To Remove Remove Cabinet Cover Battery compartment cover. Screws (2.6 × 12)......(B) × 2 Follow the procedure. Main P. C. Board Screw (2.6 × 12)......(C) × 1 Main P. C. Board...
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 7 ADJUSTMENTS (BASE UNIT) If your unit has below symptoms, adjust or confirm each item using remedy column from the table. Symptom Remedy* The base unit does not respond to a call from handset.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 7.2. How to change the channel Note: Refer to Adjustment Standard (Base Unit) (P.21) for connection. 7.3. Adjustment Adjustment Items Test Mode Adjustment *Procedure Check or Point Replace Parts • • • • Adjust T404 so that the reading of the Digital Voltmeter is 1.5 ± 0.3 V.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 8 ADJUSTMENTS (HANDSET) If your unit has below symptoms, adjust or confirm each item using remedy column from the table. Symptom Remedy* The movement of Battery Low Indicator is wrong. Make confirmation in item (A) The base unit does not respond to a call from the handset.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 8.2. How to change the channel 8.3. Adjustment Adjustment Items Test Mode Adjustment *Procedure Check or Point Replace Parts (A) Battery Low 3ch Talk 1. Adjust the power supply voltage to DC 3.60V and confirm so that the...
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 9 RF SPECIFICATION 9.1. Base Unit Item Value Refer to -.* Remarks TX Frequency 30.175 MHz ± 700 Hz ADJUSTMENTS (BASE UNIT) (C) at CH3 TX Power more than 8dBm ADJUSTMENTS (BASE UNIT) (D)
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 12 EXPLANATION OF CPU DATA COMMUNICATION 12.1. STAND-BY -> TALK, TALK -> STAND-BY *: The channel is changed if the noise interferes with the conversation.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 12.4. Ports for transmitting and receiving of data Handset: Base Unit: transmitting (TX) ... 25 Pin transmitting (TX) ... 23 Pin receiving (RX) ... 12 Pin receiving (RX) ... 10 Pin 12.5. Waveform of DATA used for cordless transmission and reception The DATA which is transmitted from the Handset to the Base Unit is combination of DATA 0, DATA 1, DATA Delimit.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 14 CIRCUIT OPERATION (BASE UNIT) 14.1. Outline Base unit consists of the following ICs as shown in BLOCK DIAGRAM (BASE UNIT) (P.31). • • • • CPU: IC201 − − − − Controlling the whole system −...
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 14.2. Power Supply Circuit The power supply to the CPU and RF IC from AC Adaptor (+12V) is shown in the diagram below. The base unit power supply is DC12V. The handset power is supplied from DC 3.6V battery (Nickel-Cadmium battery) which is installed in the handset.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 14.3. Reset Circuit After power supply from AC adaptor, the reset signal for CPU is making in IC401. Refer to the below waveform. <Fig. 2> <Fig. 3>...
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 14.4. Charge Circuit Circuit Operation: When charging the handset on the base unit, the charge current is as follows; DC12V → L101 → D102 → L103 → CH+(Base) → +CONTACT J601(Handset) → L602 → D602 → CN1-1 → Battery →...
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 14.6. Transmitter/Receiver Base Unit and Handset mainly consist of RF (Radio Frequency) IC and CPU. Base Unit and Handset transmit/receive voice signal and data signal through the antenna on carrier frequency. Signal Path: *Refer to CDL TX/RX in SIGNAL ROUTE (P.41).
Page 37
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 14.6.3. RF signal operation/control and PLL operation (RF UNIT) Base unit radio frequency signal received by antenna passes through duplexer (DPX401). RF signal is amplified by RF AMP. RF signal received from RF IC is mixed with RX local frequency at Mixer to generate 10.7 MHz wide band IF.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 16.3. Battery Low / Power Down Detector Circuit Operation: “Battery Low” and “Power Down” are detected by RF IC which check the voltage from battery. Shortly, every detected blocks are inside of RF IC. The detected voltage is as follows;...
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 21 HOW TO REPLACE THE FLAT PACKAGE IC Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a soldering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 21.3. FLAT PACKAGE IC INSTALLATION PROCEDURE 1. Temporarily fix the FLAT PACKAGE IC, soldering the two marked pins. *Check the accuracy of the IC setting with the corresponding soldering foil. 2. Apply flux to all pins of the FLAT PACKAGE IC.
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 26 REPLACEMENT PARTS LIST 1. RTL (Retention Time Limited) Ref. Part No. Part Name & Description Remarks Note: PQBC10428Z1 BUTTON, LOCATOR (for KX- ABS-HB TC2106UAB) The marking (RTL) indicates that the Retention Time is...
Page 52
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW Ref. Part No. Part Name & Description Remarks Ref. Part No. Part Name & Description Remarks L301 PQLQZK3R3K COIL R409 ERJ3GEYJ563 L302 PQLQZK3R3K COIL R410 ERJ3GEYJ333 L401 PQLQZK2R2K COIL R412 ERJ3GEYJ823 T401 G2BRC0000010...
KX-TC2106UAB / KX-TC2106UAS / KX-TC2106UAT / KX-TC2106UAW 27 FOR SCHEMATIC DIAGRAM 27.1. Base Unit (SCHEMATIC DIAGRAM (BASE UNIT)) 1. DC voltage measurements are taken with an oscilloscope or a tester with a ground. 2. The schematic diagrams and circuit board may be modified at any time with the development of new technology.