Operation

Query indoor performance state:
In normal state, press both buttons of [CHECK] and [FILTER] for 5 seconds, in the set temperature
region in the screen, [XX] will display, XX is indoor number, which can be selected by pressing [TEMP]
[+] [-]. In the timer region in the screen, [YZZZ] will display, in which Y stands for data type, ZZZ
stands for the corresponding data. which can be selected by pressing [CLOCK] [+] [-].
Y
ZZZ
A
Indoor capacity (W)
B
Request of indoor capacity(Hz)
C
Temperature of indoor ambient temp. sensor TA Actual value, decimal
d
Temperature of indoor gas pipe sensor TC1
E
Temperature of indoor liquid pipe sensor TC2
F
Open degree of indoor PMV
g
Preset
H
Outdoor total capacity
In check mode, press [CHECK] to quit the check mode, and go into normal running mode.
Type
Nominal cooling capacity/10, decimal
Actual value, decimal
Actual value, decimal
Actual value, decimal
Actual value, decimal
---
Actual value, decimal