GE CS5500 Programming Manual page 57

Table of Contents

Advertisement

Term
Exit Error
Exit Expiry
Exit route
Exit time
Exit time buzzer
Expander board
Expander Trouble
Expander Trouble and
Restores
Expansion modules
External Contact
External Siren Timeout
F
Definition
A menu option that specifies that the control panel sends an exit error report if an
entry/exit zone is faulted when the exit delay expires. This report is sent along with
the user number that armed the system, if the panel is not disarmed before the
entry delay expires. The alarm report is also sent. Even if this feature is not
enabled, the siren sounds if any entry/exit zone is faulted when the exit delay
expires.
A menu entry that groups the report codes sent to the central station if an alarm is
created during the exit time. (Report Codes)
A menu option that causes the internal sounder to blast when the exit time
expires.
The route the user must follow to exit a secured area after arming the system.
The time within which the user must exit the secured area after arming the system
before a full alarm occurs. This time can be between 10 and 255 seconds.
A sounder indicating that the system is in exit time waiting to complete arming.
The exit time buzzer does not sound for silent exit.
The control panel can be used with additional boards which provide extra
functionality.
These include:
CS208/CS216 Input Expanders
CS507 Output Expanders
CS586 Direct Connect Module
CS534 Listen-in Module
CS320 Power Modules
CS535 Voice Module
CS1700 Proximity Readers
CS7001 GSM Module
Receiver Modules
A menu option that activates the internal sound when an expander trouble
condition occurs. (Internal Siren)
A menu option that activates the keypad buzzer when an expander trouble
condition occurs. (Keypads)
A menu option that sends a report to the central station when an expander trouble
condition occurs. (System Reports)
A menu entry that groups report codes sent to the central station when an
expander trouble event occurs. (Report Codes)
A menu option that sends a report to the central station when the control panel
detects expander trouble. A report is also sent when the trouble condition is fixed.
(Reports)
A menu option that sends an expander trouble and restore report to the selected
phone number. (Phone Numbers)
A menu option that sends expander trouble and restore reports to the central
station depending on the condition of the panel dialler. (CS7001 GSM Module)
See also Panel Dialler OK Events and Panel Dialler Not OK Events
See Expander board
A menu option on an RF door/window sensor that enables an additional external
contact. When the external contact is triggered, an alarm is generated on the
same zone number as the door/window sensor (reed contact) itself.
A menu option that sets the length of time an external sounder/siren rings before
automatically cutting out. A new alarm trip reactivates the external sounder for the
length of time specified in this option. This time can be between 0 and 255
minutes. When set to 0, the siren is active until a valid code is entered on the
keypad.

Hide quick links: