Mitsubishi Electric FR-D720-008 Installation Manuallines page 19

Hide thumbs Also See for FR-D720-008:
Table of Contents

Advertisement

PARAMETER LIST
Name
Pr.
57
Restart coasting time
58
Restart cushion time
59
Remote function selection
Energy saving control
60
selection
65
Retry selection
Stall prevention operation
66
reduction starting frequency
Number of retries at fault
67
occurrence
68
Retry waiting time
69
Retry count display erase
Special regenerative brake
70
duty
71
Applied motor
72
PWM frequency selection
73
Analog input selection
74
Input filter time constant
Reset selection/disconnected
75
PU detection/PU stop
selection
77
Parameter write selection
Reverse rotation prevention
78
selection
79
Operation mode selection
80
Motor capacity
82
Motor excitation current
83
Rated motor voltage
84
Rated motor frequency
90
Motor constant (R1)
96
Auto tuning setting/status
PU communication station
117
number
118
PU communication speed
PU communication stop bit
119
length
PU communication parity
120
check
Number of PU communication
121
retries
PU communication check
122
time interval
PU communication waiting
123
time setting
PU communication CR/LF
124
selection
Terminal 2 frequency setting
125
gain frequency
Terminal 4 frequency setting
126
gain frequency
PID control automatic
127
switchover frequency
128
PID action selection
16
Initial
Setting Range
Value
0, 0.1 to 5s,
9999
9999
0 to 60s
1s
0, 1, 2, 3
0
0, 9
0
0 to 5
0
0 to 400Hz
60Hz
0 to 10,
0
101 to 110
0.1 to 600s
1s
0
0
0 to 30%
0%
0, 1, 3, 13, 23,
0
40, 43, 50, 53
0 to 15
1
0, 1, 10, 11
1
0 to 8
1
0 to 3, 14 to 17
14
0, 1, 2
0
0, 1, 2
0
0, 1, 2, 3, 4, 6, 7
0
0.1 to 7.5kW,
9999
9999
0 to 500A, 9999
9999
200V/
0 to 1000V
400V
∗5
10 to 120Hz
60Hz
0 to 50Ω, 9999
9999
0, 11, 21
0
0 to 31
0
(0 to 247)
48, 96, 192, 384
192
0, 1, 10, 11
1
0, 1, 2
2
0 to 10, 9999
1
0,
0.1 to 999.8s,
9999
9999
0 to 150ms,
9999
9999
0, 1, 2
1
0 to 400Hz
60Hz
0 to 400Hz
60Hz
0 to 400Hz,
9999
9999
0, 20, 21,
0
40 to 43
Name
Pr.
129
PID proportional band
130
PID integral time
131
PID upper limit
132
PID lower limit
133
PID action set point
134
PID differential time
PU display language
145
selection
146
Parameter for manufacturer setting. Do not set.
150
Output current detection level 0 to 200%
Output current detection
151
signal delay time
152
Zero current detection level
153
Zero current detection time
Stall prevention operation
156
selection
157
OL signal output timer
158
AM terminal function selection
Extended function display
160
selection
Frequency setting/key lock
161
operation selection
Automatic restart after
162
instantaneous power failure
selection
Stall prevention operation
165
level for restart
Output current detection
166
signal retention time
Output current detection
167
operation selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
171
Operation hour meter clear
STF terminal function
178
selection
STR terminal function
179
selection
180
RL terminal function selection
RM terminal function
181
selection
182
RH terminal function selection
Initial
Setting Range
Value
0.1 to 1000%,
100%
9999
0.1 to 3600s,
1s
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0.01 to 10.00s,
9999
9999
0 to 7
1
150%
0 to 10s
0s
0 to 200%
5%
0 to 1s
0.5s
0 to 31, 100,
0
101
0 to 25s, 9999
0s
1 to 3, 5,
8 to 12, 14, 21,
1
24, 52, 53, 61,
62
0, 9999
0
0, 1, 10, 11
0
0, 1, 10, 11
1
0 to 200%
150%
0 to 10s, 9999
0.1s
0, 1
0
0, 10, 9999
9999
0, 9999
9999
60
0 to 5, 7, 8, 10,
12, 14, 16, 18,
61
24, 25, 60
,
∗7
0
61
, 62, 65 to
∗8
67, 9999
1
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents