A B B devic es Pos: 13 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Umwelt (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - ABB Elektrogeräte @ 19\mod_1323162745839_15.docx @ 110867 @ @ 1 All packaging materials and devices from ABB bear the markings and test seals for proper disposal. Always dispose of the packaging material and electric devices and their components via the authorized collecting depots and disposal companies.
Page 4
User Manual ABB-Welcome Pos: 17 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1 | 0073-1-7516 — 4 —...
Page 6
Operation ABB-Welcome F unc tion Press this button accept a call. Press this button to open the door. Press this button to deactivate the doorbell. While a call is pending, this button has the "reject call" function. - Press this button reject a call.
Operation ABB-Welcome Pos: 39 /DinA4 - Anleitungen Online/Ueberschriften/3./Ereignis- und Bildspeicher - History @ 20\mod_1323264954284_15.docx @ 112093 @ 3 @ 1 5.2.5 E vents and pic ture memory / his tory Pos: 40 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83220-AP-xxx/Ereignis- und Bildspeicher - History - 83220-AP-xxx @ 20\mod_1323265076529_15.docx @ 112101 @ @ 1 The panel records all events.
Page 13
Operation ABB-Welcome Fig. 8: Events and picture storage / history | 0073-1-7516 — 13 —...
Page 14
Operation ABB-Welcome During a call you can take a snapshot at any time by pressing the "History" button, even when the "Automatic snapshots" function is not active. The following functions are available for the "Events and picture storage /history" function.
Page 17
Operation ABB-Welcome Fig. 11: Settings To change into the settings areas of the list field (1), carry out the following steps: 1. To display the hidden functions, tip on the scroll buttons (2). 2. Touch one of the setting areas.
Operation ABB-Welcome Pos: 52 /DinA4 - Anleitungen Online/Ueberschriften/4./Display @ 20\mod_1323859069487_15.docx @ 112267 @ 4 @ 1 5.2.7. 3 Dis pla y Pos: 53 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83220-AP-xxx/Einstellungen Display- 83220-AP-xxx @ 20\mod_1323859176842_15.docx @ 112275 @ @ 1 Fig. 13: Display settings When changing to "Display", the following functions become available:...
Page 20
Operation ABB-Welcome Screen saver Off – Select the active period for the screen saver via the fold-down menu until it switches itself off automatically. – Available are 5 / 15 / 30 minutes. – To protect the display the maximum period for the display is limited to 30 minutes.
Operation ABB-Welcome Pos: 55 /DinA4 - Anleitungen Online/Ueberschriften/4./Datum - Uhrzeit @ 20\mod_1323862082869_15.docx @ 112283 @ 4 @ 1 5.2.7. 4 Date / time Pos: 56 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83220-AP-xxx/Einstellungen Datum-Uhrzeit - 83220-AP-xxx @ 20\mod_1323862147113_15.docx @ 112291 @ @ 1 Fig. 14: Settings of the date and time With the change to "Date and time"...
Operation ABB-Welcome Pos: 58 /DinA4 - Anleitungen Online/Ueberschriften/4./Sprache @ 20\mod_1323864236322_15.docx @ 112299 @ 4 @ 1 5.2.7. 5 L anguage Pos: 59 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83220-AP-xxx/Einstellungen Sprache- 83220-AP-xxx @ 20\mod_1323865579258_15.docx @ 112307 @ @ 1 Fig. 15: Setting the language When changing to "Language"...
Page 23
Operation ABB-Welcome F oreign language is s et If a foreign language has been set, take the following steps for a reset: 1. Tip on the "Settings" button below the display. 2. In the list field of the "Settings" display (on the left in the display) tip on the 4th entry from the top (this entry is marked with a flag).
Operation ABB-Welcome Pos: 67 /DinA4 - Anleitungen Online/Ueberschriften/2./Reinigung @ 19\mod_1310733980533_15.docx @ 107853 @ 2 @ 1 C leaning Pos: 68 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/Reinigung/Reinigung Touchscreenmonitor @ 19\mod_1310734108978_15.docx @ 107862 @ @ 1 Caution R is k of da ma ge to the s c reen s urfa c e.
Mounting / Installation ABB-Welcome Pos: 84 /Busch-Jaeger (Neustruktur)/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 2 @ 1 Mounting Pos: 85.1 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/83220-AP-xxx/Montage - Module/Montage - Montagedose -- 83220-AP-xxx @ 19\mod_1323250406848_15.docx @ 111098 @ @ 1 Installation on an FM socket according to DIN 49073-1, or directly on a level wall surface.
Page 31
Mounting / Installation ABB-Welcome Fig. 22: 2. Fix the bottom of the device to the wall. Fig. 23: 3. Connect the bottom part of the device according to the graphics (see chapter "Connection" on page 34). Fig. 24: | 0073-1-7516...
Page 32
Mounting / Installation ABB-Welcome Set the address of the preferred outdoor stations and the address of the indoor station on the rotary switches (see chapter "Addressing" on page 35). Fig. 25: 5. Set the master/slave function and the terminal resistor on the switches at the rear of the top part of the housing (see chapter "Setting the master/slave switch"...
Page 33
Mounting / Installation ABB-Welcome Fig. 26: Latch the upper part of the device onto its bottom part. To do this, place the upper side of the device on the lock-in lugs and then press the bottom side onto the bottom part of the device until the clamp catches.
Addressing ABB-Welcome Pos: 90 /DinA4 - Anleitungen Online/Ueberschriften/1./Adressierung @ 18\mod_1302616059553_15.docx @ 103432 @ 1 @ 1 Addressing Pos: 91 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/Adressierung/Adressierung-Projektierung @ 20\mod_1324287710173_15.docx @ 112353 @ 233333 @ 1 A ddres s ing the s ta tions 8.1.1 P otentiometer Before installing as system, it must must be addressed.
Addressing ABB-Welcome 8.1.5 S etting of the " s tandard outdoor s tation" For several outdoor stations in a system the "standard outdoor station" must be set on the indoor stations. For this the potentiometer STATION is set on the address of the standard outdoor station - between 1 and 4.
Page 37
Addressing ABB-Welcome Fig. 31: Several outdoor stations with identical assignment Des igna tion Main entrance outdoor station Side entrance outdoor station Apartment 01 Apartment 02 Apartment 03 | 0073-1-7516 — 37 —...
Addressing ABB-Welcome Fig. 32: Several outdoor stations with identical assignment Des igna tion Apartment 01 Apartment 02 Outdoor station of the left building Outdoor station of the entrance gate Outdoor station of the right building Apartment 03 Apartment 04 Pos: 92 /DinA4 - Anleitungen Online/Ueberschriften/2./Video zur Adressierung des Geraetes @ 19\mod_1322130240851_15.docx @ 110503 @ 2 @ 1 V ideo for addres s ing the devic e Pos: 93.1 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/Video-Module/Einleitungen/Einleitung - Adressierung des Geraetes @ 20\mod_1324552270462_15.docx @ 112509 @ @ 1...
Page 39
Addressing ABB-Welcome Pos: 95 /DinA4 - Anleitungen Online/Inhalt/KNX/DoorEntry/Projektierung-Merkblatt/Projektierung-Merkblatt - ABB @ 19\mod_1323176717034_15.docx @ 111044 @ @ 1 Project name: Mounting position for the outdoor station: Floor 02 === Ende der Liste für Textmarke Content === | 0073-1-7516 — 39 —...
Page 40
Busch-Jaeger Elektro GmbH contents of this document without prior notice. The detailed specifications agreed to at the time PO box of ordering apply to all orders. ABB accepts no 58505 Lüdenscheid responsibility for possible errors or incompleteness in this document.