hp uninterruptible
power system
R1500 xr models

installation instructions

Read Instructions Completely
Before Beginning Installation Procedures
Hewlett-Packard Company shall not be liable for technical or editorial errors or
omissions contained herein. The information in this document is provided "as is"
without warranty of any kind and is subject to change without notice. The warranties
for HP products are set forth in the express limited warranty statements
accompanying such products. Nothing herein should be construed as constituting an
additional warranty.
HP Uninterruptible Power System R1500 XR Models Installation Instructions
Second Edition (August 2002)
Part Number 215859-022
215859- 022
Overview
These instructions show how to install an uninterruptible power
system (UPS). For detailed information about the UPS, refer to the
UPS user guide on the Power Products Documentation CD.

Important Safety Information

Before installing this product, read the Important Safety
Information document provided.
WARNING: To prevent personal injury from electric shock and
hazardous energy levels, the installation of options and routine
maintenance and service of this product must be performed by
individuals who are knowledgeable about the procedures,
precautions, and hazards associated with AC power products.
WARNING: To prevent personal injury from earth conductor
leakage current:
Do not operate a UPS that is disconnected from the utility
power source.
Disconnect protected devices from the UPS before
disconnecting the UPS from utility power.
Use the Test/Alarm Reset button to test the batteries rather
than unplugging the UPS. Refer to the UPS user guide for
more information on the operation of the UPS.
Regulatory Compliance
Identification Numbers
For regulatory compliance certifications and identification
purposes, the UPS models are assigned a series number, also
identified on the Regulatory Compliance label located on the
side of the UPS. For certification information, always refer to
the series number:
• R1500 XR NA series number: EO3008
• R1500 XR JPN series number: EO3008j
• R1500 XR H INT'L series number: EO3008i
NOTE: The rating label on the device provides the class (A or B) of the
equipment. Class B devices have a Federal Communications Commission
(FCC) logo or FCC ID on the label. Class A devices do not have an FCC logo
or FCC ID on the label. After you determine the class of the device, refer to
the UPS user guide for complete regulatory compliance notices.
Weight
WARNING: The UPS weighs 24 kg (52 lb) when fully
assembled. To prevent personal injury or damage to
the equipment:
24 kg
Observe local occupational health and safety
52 lb
requirements and guidelines for manual material
handling.
Obtain adequate assistance to lift and stabilize the
product during installation or removal. The UPS is
unstable when not fastened to the rails.
Remove the battery pack to reduce the overall
weight of the product.

Advertisement

Table of Contents
loading

Summary of Contents for HP r1500 xr

  • Page 1: Important Safety Information

    The warranties product during installation or removal. The UPS is for HP products are set forth in the express limited warranty statements unstable when not fastened to the rails.
  • Page 2: Checking The Battery Recharge Date

    • The R1500 XR NA model ships with a non-detachable input power cord with a NEMA 5-15 plug and a 3.66-meter (12-foot) IMPORTANT: Do not use the battery if the recharge date has passed. If the UPS/computer interface cable (201092-002).
  • Page 3: Electrical Requirements

    WARNING: Risk of personal injury from electric shock. The UPS R1500 XR H INT’L model is not suitable for installation where the total earth (ground) conductor leakage current for all connected devices exceeds 3.5 mA. You may use RackBuilder Pro (obtainable from www.hp.com) to find the total system...
  • Page 4 4. Insert the screws supplied in the UPS kit through each Installing the UPS in the Rack rack-mounting rail and into the front of each rack. Before attempting to install the UPS, review and adhere to all warnings provided in the “Important Safety Information” section of this document.
  • Page 5: Connecting The Network Transient Protector

    4. Replace the connector block in the REPO port. Connecting the Network Transient Protector The Network Transient Protector allows the UPS to protect a communications device from surges. IMPORTANT: To avoid damaging the equipment, use the Network Transient Protector with a standard telephone line only, not with a digital PBX.
  • Page 6: Placing The Ups In Operate Mode

    • Utility LED (5): Connecting the UPS to Utility Power  Flashing Red – Utility input voltage is outside the +20% to Connect the UPS to a grounded utility power outlet. -30% configured nominal range. WARNING: To prevent personal injury from electric shock or ...
  • Page 7: Shutting Down The System

    2. Press the Standby button to take the UPS out of Operate mode. Power to the load receptacles ceases. 3. Disconnect the UPS from utility power. 4. Wait at least 60 seconds while the UPS internal circuitry discharges. For more information, refer to the HP website at www.hp.com/products/ups...