(3) Remove the carbon brushes from the brush holders.
Assembly
(1) Insert the new carbon brushes into the brush holders.
(2) Insert the brush holders together with the carbon
brushes into the brush holder chambers in the
housing.
(3) Ensure that the lead wire and other parts are properly
positioned, and that there is no possibility of the lead
wire coming in contact with the armature or other
moving parts.
(4) Reinstall the handle cover while ensuring that the
internal wiring does not become pinched between
the handle cover and the housing, and secure the
handle cover with the three screws.
CAUTIONS
Be sure to follow the above assembly procedures
exactly. Should the internal wiring contact the
armature or become pinched between the handle
cover and housing, a serious risk of electric shock to
the operator would be created.
Do not tamper with parts other than those necessary
to effect carbon brush replacement.
NOTE
Due to HITACHI's continuing program of research and
development, the specifications herein are subject to
change without prior notice.