Downdraft vent system
Table of Contents

Advertisement

Available languages

Available languages

VENTING OPTIONS
• The downdraft vent is shipped with the
discharge outlet pointing straight down and
can be changed to the left or right side.
• The blower outlet is sized for 3-1/4" x 10"
and can be transitioned to 6" round.
Side-to-Side Adjustments:
The entire blower mounting plate can be
adjusted 3-1/2" to the left or right. This
will help to align vent discharge to house
ductwork.
4-1/4"
17-1/4"
Discharge Down
(As Supplied)
Discharge Direction
The blower assembly may be removed and turned 90°
for a left- or right-side discharge.
• A left or right 90° direction adjustment should be
performed before dropping into the countertop
opening.
To change to a left or right discharge:
• Remove the 4 screws holding the blower and the
mounting plate assembly to the downdraft vent.
Retain screws.
• Remove blower assembly; turn it over to access
the 4 nuts holding the blower to the mounting plate.
Remove the nuts.
49-80777
Installation Preparation
Discharge Down
16-3/8"
4-1/4"
Discharge Left
Loosen Screws
to Adjust
3-1/2" to
Left or Right
(As Supplied)
IMPORTANT: Do not lift motor by the power cable.
• Turn the blower to the left or right discharge
direction and reinstall the 4 nuts.
• Reinstall blower and mounting plate with original
screws.
• The hood must vent down or to the left when
installed with a GE or Monogram gas cooktop to
avoid interference with the inlet of the gas cooktop.
10-5/16"
4-1/4"
Discharge Right