Download Print this page

Radios And Antennas; Reset Button; Status Leds - HP MSM415 Quick Start Manual

Hide thumbs Also See for MSM415:

Advertisement

Ports
Ethernet port (Port 1): Auto-sensing 10/100/1000
Base-T Ethernet port with RJ-45 connector. This port
supports Power over Ethernet (PoE) 802.3af.
Console port: Standard console (serial) port with an
RJ-45 connector.
Caution: Never connect the console port to an Ethernet
switch or PoE power source. This may damage the
sensor. Connect it only to other serial ports via an
RJ-45 to DB-9 adapter or equivalent.

Radios and Antennas

The sensor contains an integrated single 802.1 1n
Draft 2 compliant radio with an internal three-element,
dual-band MIMO antenna.

Reset button

The reset button is accessible via a hole on the bottom
of the sensor. To perform a reset, the unit must be
powered. Insert a paper clip under the cable and into
the reset button hole at the precise angle shown. Press
and quickly release the button to reset the sensor. To
reset the sensor to factory defaults, press the button
until the status LEDs flash three times, then release.

Status LEDs

The following table indicates various MSM415 Sensor
states using the LEDs on the sensor device. Because
there is one wireless interface used for both 2.4 GHz
and 5 GHz, some states are overlapping.
Power
Ethernet
On
On
On
On
On
On
On
Flashing
slowly
Flashing
On
slowly
Flashing
Flashing
quickly
quickly
Flashing
Flashing
slowly
slowly
Flashing
slowly
Flashing
slowly
Off
Off
Page 2
Radio
Description
On
The sensor is receiving power and
is working normally. The sensor is
also connected to the HP RF
Manager server.
Flashing
The sensor is performing
quickly
troubleshooting on
802.1 1b/g/n.
The sensor is performing
troubleshooting on
802.1 1a/n.
The sensor is performing
troubleshooting on 802.1 1a/n
and 802.1 1b/g/n.
The sensor is performing
troubleshooting on 802.1 1a/n
and intrusion prevention on
802.1 1b/g/n.
Flashing
The sensor is performing
slowly
intrusion prevention on
802.1 1b/g/n.
The sensor is performing
intrusion prevention on
802.1 1a/n.
The sensor is performing
intrusion prevention on
802.1 1a/n and
troubleshooting on
802.1 1b/g/n.
The sensor is performing
intrusion prevention on
802.1 1a/n and
802.1 1b/g/n.
Flashing
The sensor upgrade is in progress.
slowly
The sensor is unable to get
Ethernet link.
The sensor did not receive a valid
IP address via the DHCP.
The sensor is unable to connect to
the RF Manager server.
On
There is an error on wireless
interface of the sensor.
The sensor is experiencing a
software error.
Off
The sensor is not powered on or
it is in the process of starting up.

Advertisement