Mitsubishi Electric DX-TL308E series Operation Manual page 8

Hide thumbs Also See for DX-TL308E series:
Table of Contents

Advertisement

Command code table (continued)
RS-232C [Direct operation specifi cation] operation setting command form (4/7)
Command name
Clear warning
WC*
display
Load/save menu data MC,*
MC,00100 ≤
Initialize menu
Clear data
CL,**
Construct alarm list IFC01,**
****
**
**
(7)
**
(11)
Command
RC ≥
(1)
(2)
EX,**
**
(3)
**
**
RC ≥
(1)
(2)
(3)
(4)
EX,**
**
(3)
,**
RC ≥
(1)
EX,**
**
(2)
**
RC ≥
(1)
(2)
(3)
EX,**
**
(4)
**
**
RC ≥
(1)
(2)
(3)
****
**
(4)
(5)
(6)
(12)
EX,**
**
**
**
**
(8)
(9)
(10)
(2)
****
(5)
**
**
(8)
**
(11)
,****
Status
*
(1)
:Clearing warning display command
(1)
WC*
,
0:Clear
**
(2)
:Error type (Refer to page 4.)
**
(3)
:System mode number (Refer to Power command)
*
(1)
:Menu loading/saving command
**
(1)
(2)
MC,*
1:Load
**
**
(5)
(6)
(2)
:Device to be loaded/saved
02:Copy
**
(3)
:Device group to be loaded/saved
<For Copy>
03:DVD/CD
<For Internal memory>
06:Inernal memory
**
(4)
:Error type (Refer to page 4.)
**
(5)
:Data error type
00:No error
20:No data
22:Unavailable data (Unconformable partition setting)
**
(6)
:System mode number (Refer to Power command)
**
(1)
:Error type (Refer to page 4.)
**
(2)
MC,00100,
:System mode number (Refer to Power command)
**
(1)
:Device including the data to be cleared
**
(1)
(2)
CL,**
,
01:Main
**
(2)
:Device group including the data to be cleared
<For Main>
01:Normal
<For Copy>
00:SerialBus
<For Archive>
00:SerialBus
**
(3)
:Error type (Refer to page 4.)
**
(4)
:Data clearing mode number
00:End
**
(1)
:Alarm list construction device
(1)
IFC01,**
01:Main
****
**
(3)
(4)
(2)
:Alarm list construction device group
**
**
(6)
(7)
<For Main>
**
(9)
(10)
01:Normal
(13)
<For Copy>
00:SerialBus
<For Archive>
00:SerialBus
**
(3)
:Direction
00:Forward direction from specifi ed time
01:Reverse direction from specifi ed time
02:Forward direction from end point of previous construction
03:Reverse direction from start point of previous construction
04:Starts construction from start point of the specifi ed
device (forward direction)
05:Starts construction from end point of the specifi ed
device (reverse direction)
****
(4)
:The number of list items
0000-1000
****
(5)
:Sensor to be searched
Shown using hexadecimal number. Bit allocation for
each sensor
LSB=sensor 1 Ex. "003F" indicates sensor numbers 1 to 6.
**
(6)
:Specifi ed time/year (01-37)
**
(7)
:Specifi ed time/month (01-12)
**
(8)
:Specifi ed time/day (01-31)
**
(9)
:Specifi ed time/hour (00-23)
**
(10)
:Specifi ed time/minute (00-59)
**
(11)
:Specifi ed time/second (00-59)
**
(12)
:Error type (Refer to page 4.)
****
(13)
:The number of items to be constructed
0000-1000
8
Note
2:Save
04:Internal memory
04:USB memory
10:No device
11:No medium
21:Improper data
02:Copy
03:Archive
02:Alarm
03:Emergency
03:DVD/CD
04:USB memory
02:Data clearing error
02:Copy
03:Archive
02:Alarm
03:Emergency
03:DVD/CD
04:USB memory

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dx-tl304e series

Table of Contents