Hitachi 50VF820 Service Manual page 71

Hide thumbs Also See for 50VF820:
Table of Contents

Advertisement

TC90103 (9/12)
Adjustment
Adjustment Item
Mode OSD
TC90103
ANT/NTSC/480i
141
2 Field Assistance Select
00h:Y, 01h:C
142
2 Field Assistance Color Still Picture Distinction
Level
00h: Small ~ 07h:Large [04h: Default]
143
2 Field Assistance Y Still Picture Distinction Level
00h: Small ~ 07h: Large [04h: Default]
144
1 Field Detection Still Offset Adjustment for Still
Picture Cross Color Improvement
00h:OFF
~0Fh:Compulsion Still Picture 2 Step [0Ah: Default]
145
2 Field Detection Still Picture Offset Adjustment for
Still Picture Cross Color Improvement
00h:OFF~0Fh:Still Picture Distinction
146
Motion Detection Error, Compulsion Motion Picture
at Vicinity of 3. 4MHz
Still Color Signal Level Threshold (Still Picture Color Detect
ion)
00h:OFF~0Fh:15/1023 (1Lsb Step)[00h: Default]
147
Motion Detection Error, Compulsion Motion Picture
at
Vicinity of 3. 4MHz
Still Picture Color Signal Level Threshold
(Still Picture No Color Detection)
00h:OFF~0Fh:15/1023 (1Lsb Step)[00h: Default]
148
[NR] Band Select
00h:Wideband, 01h: Narrowband
149
Y Differential Color Level Detection
00h:Motion Detection OFF, 01h:Nonlinear
Processing
150
Y Non Correlation Detection Level Switch
00h:[4:0], 01h:「5:1」
151
Color Non Correlation Detection Level Switch
00h:[5:1], 01h:「6:2」
152
[NR] Y Differential Color Level Y Motion Picture
Distinction Level
00h:Motion Picture ~ 0Fh:Still Picture [08h: Default]
153
AGC Manual Setting (AGC = Auto Gain Control)
00h:OFF, 01h:ON
154
AGC Manual Gain Setting
(AGC = Auto Gain Control)
155
AGC Sync Level Detection ON/OFF
(AGC = Auto Gain Control)
00h:OFF, 01h:ON
BACK TO ADJUSTMENTS
Adjustment
Initial Data(HEX)
Range(HEX)
LC58E LC58
LC57
00~01
00
00~07
04
00~07
04
00~0F
04
00~0F
02
00~0F
00
00~0F
00
00~01
00
00~01
00
00~01
00
00~01
00
00~0F
08
00~01
00
00~7F
28
00~01
01
TC90103 (10/12)
Adjustment
Mode OSD
TC90103
ANT/NTSC/480i
156
AGC Peak Level Detection ON/OFF
(AGC = Auto Gain Control)
00h:OFF, 01h:ON
157
AGC OFF/ON Level Setting
(AGC = Auto Gain Control)
00h:OFF, 01h:70%, 02h:75%, 03h:80%
158
GCA Setting (GCA = ?)
00h:Auto, 01h:Digital
159
AGC Response Time Setting
(AGC = Auto Gain Control)
00h:Fast ~ 07h:Slow
160
Peak AGC Level (AGC = Auto Gain Control)
00h:105%, 01h:110%, 02h:115%, 03h:120%
161
GCA Gain Switch (GCA = ?)
00h:-3~+7dB, 01h:+6dB,
02h:–5~+5dB, 03h:–6~+4dB
162
Pedestal Difference Detection ON/OFF
00h:OFF, 01h:ON
163
Peak AGC Discharge Speed
00h:Fast ~ 07h:Slow
164
AGC Pedestal Timing for Digital Clamp
(AGC = Auto Gain Control)
08h:-1. 19us ~ 00h:(Center) ~ 07h:+1. 04us
165
AGC Sync Timing for Digital Clamp
08h:-1. 19us ~ 00h:(Center) ~ 07h:+1. 04us
166
Horizontal Phase Adjustment for Digital Format
08h:-1. 185us ~ 00h: 0us ~ 0Fh:+1. 04us
167
Vertical Phase Adjustment for Digital Format
00h:0H ~ 0Fh:+15H
168
Vertical Horizontal Start Phase at Vertical Through
00h:0W, 01h:64W, 02h:128W, 03h:192W,
04h:256W, 05h:320W, 06h:348W, 07h:Prohibition
169
VD at Non Standard Output
00h:Horizontal Count Standard,
01h:Vertical Separation Standard
170
656 Non Conforming Horizontal Out Phase
00h:32W, 01h:36W, 02h:40W, 03h:44W
71
Adjustment Item
Adjustment
Range(HEX)
LC58E LC58
00~01
01
00~03
00
00~01
00
00~07
00
00~03
01
00~03
01
00~01
00
00~07
00
00~0F
08
00~0F
08
00~0F
08
00~0F
00
00~07
00
00~01
01
00~03
00
LC58/LC58E
Initial Data(HEX)
LC57

Hide quick links: