Nokia 3210 Service & Repair Manual page 32

Nokia cell phone service and repair hints
Hide thumbs Also See for 3210:
Table of Contents

Advertisement

Figure 8:PLL-SDAT Signal
Figure 9:PLL-SENA Signal
No RX (no Rx calibration...RSSI reading fixed value)
COBBA / MAD faulty /broken solder balls
Check if the 13MHz IF on pin 23,24 N700 SUMMA change the amplitude if you change the generator frequency
level
Check if the RXC impulse on pin 36 N700 (SUMMA) change the amplitude if the generator frequency level is
modified (see the diagram below)
Check R725 if any or low signals are measurable
Change COBBA N200(rewrite SIMLOCk and update the handset)
If the fault persist MAD or the PCB should be the reason
In this case swap the handset because MAD is not changeable
Note! Rewrite SIMLOCK and IMEI entries with use of the Nokia security SW (SSSW) and make a SW-update or send
this phones to the SACE, if this procedure is not permitted to you
version 1.0 / 05.11.1999
CONFIDENTIAL
(change the operation mode first to "RX BURST MODE")
Service & Analysis Center Europe
Training Team
Page 32 of 37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents