Perforation Adjustment (Final); Sw5-Sw5' Adjustment - Canon A-1 Repair Manual

Hide thumbs Also See for A-1:
Table of Contents

Advertisement

2.
Recheck the alignment of the dowel and scribed mark
detailed in section 2-.13 (Fig. 2-15) after having
installed the charge gear with the screw access hole
positioned as shown in figure 2-20.
Adjust to main-
tain the position
by
selecting a charge gear that
gives the correct alignment.
2.16
Perforation Adjustment (Final)
Note:
Perform this adjustment after installing the charge
gear.
1
.
Install a strip of test film, wind enough to secure
i"t On the spool and then wind and hold the winding
lever at the maximum.
2
.
Pull back on the other end of the film (about 200g)
to pull the film taunt.
3.
The perforation position should be as shown in figure
2-16~
Readjust, if necessary, as stated in section
2.13
.
2.
Note:
If this adjustment is not correct, the multiple
exposure (ME) lever will not engage.
2.17
Sws-SWs' Adjustment
Caution:
If this ad
j
ustment is not correct, there is a
possibility that the camera will not function.
1.
Wind the camera.
2.
Set the brush so that it
(Fig. 2-21) Adjustment:
3.
Release the shutter
is on the check pattern.
Eccentric Screw A
4.
Recheck the brush position.
At least four segments
of the brush should be on each of
the switch pat-
terns.
(Fig. 2-21) Adjustment:
Eccentric Screw A
5.
Recheck steps 2 and 4
.
Switch condition should not
change even at the extremes of play in the brush at
each position.
37