Conversion Instructions; Gas Supply - GE pgp989 Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

GAS SUPPLY

• With the installation of this conversion kit, the cooktop
should operate on either natural gas at 4" of water
column or LP gas at 10" of water column pressure.
• The pressure regulator must be connected in series
with the manifold of the cooktop and must remain in
series with the supply line. For proper operation, the
maximum inlet pressure to the regulator must be no
more than 10" water column pressure for natural gas
and 14" water column pressure for LP gas.
• When checking the regulator, the inlet pressure must
be at least 1" greater than the regulator output
setting. If the regulator is set for 4" of water column
pressure, the inlet pressure must be at least 5". If the
regulator is set for 10" of water column pressure, the
inlet pressure must be at least 11".
IMPORTANT –
the individual shut-off valve from the gas supply piping
system during any pressure testing of that system at test
pressures greater than 1/2 psig. Isolate the cooktop from
the gas supply piping system by closing the individual
manual shut-off valve to the cooktop during any pressure
testing of the gas supply piping system at test pressures
equal to or greater than 1/2 psig.
TURN OFF GAS AND
ELECTRIC SUPPLY
BEFORE YOU BEGIN, TURN OFF THE GAS SUPPLY AT THE
SHUT-OFF VALVE. DISCONNECT THE ELECTRICAL SUPPLY
FROM THE COOKTOP.
Shut-off valve

Conversion Instructions

Disconnect the cooktop and
Electrical supply
CONVERT SURFACE BURNERS
1
A
First remove, convert and replace the left side surface
burners and then the right side surface burners.
Remove the grates, burner caps and burner heads.
Remove the screws securing the burner bases
to the burners. Pull out the electrodes without
removing the electrode leads.
Grate
B
Remove the brass orifice spud in the chimney
of each burner using a 9/32" (7 mm) nutdriver.
Install the high altitude orifice spuds in their correct
C
positions by number.
LR
LF
Natural Gas High Altitude Orifices – 5000 ft.
Location
BTUs
LF, LR
7644
RR
4620
RF
9660
LP Gas High Altitude Orifices – 5000 ft.
Location
BTUs
LF, LR
7140
RR
4620
RF
9240
D
Replace the gaskets, burner bases and electrodes.
Install the two screws in each burner base. Do not
overtighten. The maximum torque is 10 inch pounds.
Push the igniters all the way down into the burner
head.
E
Install the burner heads, burner caps and grates
in their original burner positions.
2
Burner cap
Burner head
Electrode
Burner base
screw (2)
Burner base
RR
RF
Front
Orifice Size
Marking
1.40 mm
140 N
1.12 mm
112 N
1.51 mm
151 N
Orifice Size
Marking
.80 mm
80 L
.66 mm
66 L
.91 mm
91 L