16. Always connect a test instrument's ground 10. Service technicians should remove their lead to the instrument chassis ground before watches while repairing an MWO. connecting the positive lead; always remove the instrument's ground lead last. Samsung Electronics...
Page 3
PRECAUTION with the oven energized. Servicemen should remove their watches whenever DO NOT measure the voltage in the high voltage circuit working close to or replacing the magnetron. including filament voltage of magnetron. Samsung Electronics...
2. Specifications 2-1 Table of Specifications TIMER 99 MINUTES 90 SECONDS POWER LEVEL ON TIME OFF TIME POWER SOURCE 240V 50Hz, AC M965CE POWER CONSUMPTION MICROWAVE : 1,550W 100W 4 sec 26 sec 200W 7 sec 23 sec OUTPUT POWER...
Hold Timer Button Clock / Auto Start Button Timer Auto Start Pause Start Button Pause Cancel Button Start Cancel M965CE 3-2 Features & External Views Ventilation Holes Door Safety Interlock Holes Control Panel Door Latches Open Door Push Button Glass Plate...
VOLTAGE TRANSFORMER secondary and filament terminals. It is extremely dangerous to work on or near these circuits with the oven energized. Screws H. V. Trans DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron. Samsung Electronics...
1. Insertion depth of the thin metal plate should be 0.5mm or less. 4-3-4 Removal of Key Door & Spring Remove pin hinge from Door "E" Door "E" Detach spring from Door "E" and key door. Key Door Spring Samsung Electronics...
Base Plate 8. Connect all the leads to the drive motor. Drive Motor Cover 9. Screw the deive motor cover to the base plate with a screw driver. 10. Remount the coupler in the correct position. Samsung Electronics...
Page 9
3. When installing new membrane key board, make sure that the surface of escutcheon base is cleaned sufficiently so that any problems Membrane (shorted contacts or uneven surface) can be Panel avoided. Samsung Electronics...
2. Isolate the magnetron from the circuit by disconnecting its leads. 3. A continuity check across the magnetron filament terminals should indicate one ohm or less. 4. A continuity check between each filament terminal and magnetron case should read open. Cooling Fins Samsung Electronics...
¥ Primary switch ¥ Monitor switch (COM-NC) 5. Confirm that the gap between the switch ¥ Monitor switch (COM-NO) housing and the switch actuator is no more than ¥ Door Sensing S/W 0.5mm when door is closed. Samsung Electronics...
Page 12
NOTE 1: Variations or errors in the test procedure will cause a variance in the temperature rise. Additional power test should be made if temperature rise is marginal. NOTE 2: Output power in watts is computed by multiplying the temperature rise (step E) by a factor of 91 times the of centigrade temperature. Samsung Electronics...
; CENTRAL SERVICE CENTER 5-12-2 At least once a year have the microwave energy survey meter checked for accuracy by its manufacturer. Samsung Electronics...
H.V.Transformer component test procedure and replace if it is H.V.Capacitor defective. H.V.Diode, H.V.Fuse Magnetron 4. Open or loose wiring of power relay 5. Defective primary latch switch 6. Defective power relay or Ass'y PCB Replace PCB main. Samsung Electronics...
Page 15
* 185 or Higher(sensor failed open. sensor unplugged, wiring, or smart board) * Less than 15 (shorted sensor, or smart board) NOTE : Only heater terminals (H) can be checked with ohmmeter (30½) DOOR CAUTION : DO NOT ATTEMPT TO CHECK SENSOR TERMINALS(CAN DAMAGE SENSOR). Samsung Electronics...
Exploded Views and Parts List 7-3 Door Parts List Ref. No Parts No. Description Specification Q'ty Remarks DE67-20003X SCREEN-DOOR(B) ACRYL ,T1.5,W107.4,L401.5,WHT,M965CE/XSA DE02-00125A TAPE-DOUBLE FACE ACRYL,T0.45,W9,WHT,WF103,#4420 DE64-40011A DOOR-A RESIN-ABS(HR-0370U),T2.5,M945( DE92-50127H ASSY DOOR-E COATING,BLACK,T0.8 DE64-40012A DOOR-C RESIN-PP(TB53),T2.0,CE945GF,BL DE64-40006D DOOR-KEY NYLON#66,(2021SW),BLK,M945(EUW DE61-70032A SPRING-KEY ES,HSWR,PI0.6,D5.4,L25,MW8640T...