6.7 ELECTRICAL ADJUSTMENTS
Read and perform this adjustment when repairing the
circuits or replacing electrical parts or PCB assemblies.
6.7.1 PG SHIFTER
CONDITIONS
MODE-PLAYBACK
Input Signal-Alignment Tape (GGV1183)
INSTRUCTIONS
1. Connect CH-1 on the oscilloscope to TP3001 and CH-2
to J8005.
2. Playback the alignment tape. (GGV1183)
3. Press and hold the Tracking-Auto button on the remote
control more than 2 seconds to set tracking to center.
4. Press both CH UP button on the set and the STOP
button on the set for more than 2 seconds.
6.5 H
6.5 H
5
6
CH-2
CH-1
Fig. 1-1-A
CH-2
CH-1
Fig. 1-1-B
DVR-RT501-S
6
7
7
8
A
B
C
D
E
F
91
8