  • Page 2: To Enter Programming Mode

    TO ENTER PROGRAMMING MODE: Local programming requires the use of an alpha keypad connected to the keypad terminals on the control. ✱ 1. POWER UP, then depress [ ] and [#] both at once, within 50 seconds of powering up. 2.
  • Page 3 352*5$00,1*)250 Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults. Entries shown in dashed boxes indicate partition entries for VISTA-20P only (not applicable for VISTA-15P). Field Function Data Entries Programmable Values SYSTEM SETUP ( ✱...
  • Page 4 NOTE: Entry of a number other than one specified will give unpredictable results. For fields *43- *46: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; [#+15 for F]. Enter [ ✱ ] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used.
  • Page 5 ✱ 67 RF XMTR LOW BAT REPORT CODE [00] See box on previous page. UL: must be enabled if wireless devices are used ✱ 68 CANCEL REPORT CODE [00] See box on previous page. RESTORE REPORT CODES ( ✱ 70 – ✱ 76) ✱...
  • Page 6: Reporting Options

    DOWNLOAD INFORMATION ( ✱ 94, ✱ 95) ✱ 94 DOWNLOAD PHONE No. Enter up to 20 digits, 0–9; #+11 for ' ✱ '; #+12 for '#'; #+13 for a 2-second pause. Do not fill unused spaces. If fewer than 20 digits, exit field by pressing ✱ (and press 95, if entering next field). To clear entries from field, press ✱...
  • Page 7 SYSTEM OPTIONS *180-*181 ✱ 181 50/60 HERTZ AC OPERATION 0 = 60 Hz; 1 = 50 Hz ✱ 182 CONFIGURABLE ZONE TYPE 90 Make the appropriate entry for each digit, 1-10, based on the charts provided on the next page. Each digit’s entry is the sum of the values of its selected options (0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).
  • Page 8: Configurable Zone Types Worksheets

    Configurable Zone Types Worksheets Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182-*185. Configurable zone types 92 and 93 (VISTA-20P only) can only be programmed using the downloader software. Programming Configurable Zone Type options involves entering 10 digits in data field *182 for zone type 90 and field *184 for zone type 91, where each digit represents the sum of the values of its various options as shown in the tables below.
  • Page 9 *56 ZONE PROGRAMMING WORKSHEET (VISTA-15P supports up to 32 zones: 1-6, 9-34) [default shown in brackets] Zone Zn Type Part. Report Input Type Loop Rsp. Time Serial No. Location [09] [HW] [01] [HW] [03] [HW] [03] [HW] [03] [HW] [03] [HW] [03] [HW]...
  • Page 10: Output Type

    *57 FUNCTION KEY PROGRAMMING Option Function Comments Paging Time Display Arm AWAY Arm STAY Arm NIGHT-STAY Step Arming Device Activation Device: Comm. Test Macro Key 1 Macro Key 2 Macro Key 3 Macro Key 4 Emergency Keys: Personal Emergency Silent Alarm Audible Alarm Fire Emergency Keys:...
  • Page 11 ✱ 80 OUTPUT DEFINITIONS Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes. ✱...
  • Page 12: Zone Type Definitions

    Zone Type Definitions Use this zone type if the zone is not used. Type 00 Zone Not Used • Assign to zones that are used for primary entry and exit. Type 01 • Provides entry delay if the control is armed in the Away or Stay modes. Entry/Exit Burglary #1 •...
  • Page 13 • Arms the system in Away mode when the zone is activated. Type 21 • Pushbutton units send the user number to the central station when arming or disarming. Arm-Away • User code for button must be assigned. • Disarms the system when the zone is activated. Type 22 •...
  • Page 14: Alpha Vocabulary List (For Entering Zone Descriptors)

    ALPHA VOCABULARY LIST (For Entering Zone Descriptors) (Word Space) • 057 DOOR – L – – R – – V – • 106 LAUNDRY • 059 DOWN RADIO VALVE – A – VAULT • 107 LEFT • 060 DOWNSTAIRS • 156 REAR •...
  • Page 15: Series Transmitter Input Loop Identification

    5800 Series Transmitter Input Loop Identification • All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones). •...
  • Page 16 8-PIN CONNECTOR 24-HR BATTERY STANDBY REQUIRED FOR BATTERY FUSE USED FOR 4300/1321X10 ADEMCO No. 4219 4-WIRE RELAY FIRE INSTALLATIONS. USE 12V, 17.2AH FOR REPLACEMENT, WIRED EXPANSION MODULE SMOKE DETECTOR TRANSFORMER BATTERY FOR 600mA AUX POWER. SEE USE SAME VALUE PROGRAM RELAY (8 ADD'L EOLR WIRED ZONES) CONNECTIONS CONNECTIONS AND FOR...