Upgrading the Internal Drives
The internal disc drives can be upgraded via the DRM-
6NX web interface.
Follow these steps to upgrade an internal drive:
1. Make sure you have the new software available on
the network.
2. Start the Web browser.
3. In the location/address field, enter the name or
Internet address of your DRM-6NX.
4. Click Administration.
5. Click This DRM-6NX.
6. Click on the icon that represents the device you want
to upgrade.
7. If the firmware upgrade capability is detected for the
selected drive, you can click Upgrade Firmware...
8. Locate the new software file and click OK.
TE
L 13942296513
www
.
54
http://www.xiaoyu163.com
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
Upgrading using the Parallel Port
You will need:
÷ A PC with at least a 286, 640 kb memory, MS-DOS
3.3 or greater.
÷ DRM-6NX flash loading kit consisting of:
÷ Flash loading cable
÷ Loading software: FSTPRN.EXE
÷ The file containg the new software version
How to upgrade
1. Switch off the power.
2. Remove the bonnet.
3. Disconnect the LAN cable and the SCSI connector
from the AXIS NETWORK BOARD Assy.
4. Connect the parallel cable to the PC LPT1 port and to
the 26-pin array on the AXIS NETWORK BOARD
Assy. Make sure the parallel cable connector is
mounted with the arrow, close to pin 1, facing the
ETRAX chip located in the middle of the PCB.
5. Switch on the power to the DRM-6NX.
6. Copy the flash load software (FSTPRN.EXE) and the
new software file to a common directory.
7. Start the loading sequence with the DOS command
fstprn <binary file> .
It is also possible to load the print server with the
Q Q
3
6 7
1 3
1 5
standard DOS copy command:
copy /b <binary file> LPTx (x = LPT port no.)
NOTE:
Do not forget the /b (for binary) switch in the copy
command.
How to monitor the loading procedure
When the loading is started, the network LED will start
flashing with rate of 2 Hz (loading time between 30 sec
and 4 min).
The loader will consider itself completed and the led will
flash with a rate of 0.5 Hz.
In case of error, the flashing rate will be 1 Hz (with the
on period much longer than the off period).
There will also be a message on the PC screen telling
you if the loading was successful or not.
Final steps
If you have made a software update including parameter
changes (e.g. from 1.x to 2.x) a reset to factory defaults
is required.
For restoring to the factory default settings, refer to
"Restoring Factory Default Settings" in "Troubleshooting".
co
Assemble the DRM-6NX and attach all cables.
.
9 4
2 8
0 5
8