Check the amperage of the receptacles used referring to TABLE 1, and be
■
sure not to take a current exceeding the specified amperage.
Be sure that the total wattage of all appliances dose not exceed the rated
■
output of the generator.
Style
WARNING
To take power out from the TWIST
■
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn
it clockwise to the lock position.
Be sure to ground the generator if
■
the connected electrical device Is
grounded.
NOTE :
When the
AC circuit breaker turns off during operation, the generator is over
loaded or the appliance is defective. Stop the generator immediately, check the
appliance and / or generator for overloading or detect and have repaired as
necessary by Makita factory or authorized service center.
Ampere
Receptacle
NEMA
up to 20A
L5-20R
NEMA
up to 30A
L5-30R
NEMA
up to 30A
L14-30R
up to 50A
TABLE 1
− 13−
AC plug
Description
NEMA
(REC1)
L5-20P
NEMA
Locking Receptacle
L5-30P
(REC2)
NEMA
Locking Receptacle
L14-30P
(REC3)
Locking Receptacle
(REC4)