FEATURES MODEL AGG09LVCA / AOG09LVCA AO G09/12LVCA AGG12LVCA / AOG12LVCA AGG14LVCA / AOG14LVLA AO G14LVLA FEATURES Energy efficiency class MODEL AG G09LVCA AG G12LVCA AG G14LVCA Cooling Heating All DC ...
Flexible & easy installation Piping space is wide and connection work is easy. Beneath standard window Standard concave portion Wall Half concealed (Optional parts necessary) Min.940 Min. Min. Min. 730 Max. Max. 150 (unit:mm) (unit:mm) : t i : t i Choice of 6-direction drain &...
WIRELESS REMOTE CONTROLLER FEATURES 4 mode timer setup available (ON / OFF / PROGRAM / SLEEP). Easy operation. Easy to change signal code (max. 4 units) by button operation. Simple function setting ...
Page 7
FUNCTIONS Signal transmitter MODE button 10°C HEAT button SET TEMP. button ( ECONOMY button SLEEP button TIMER MODE button FAN button START/STOP button SET button SWING button TIMER set ( ) button CLOCK ADJUST button TEST RUN button •This button is used when installing the air conditioner, and should not be used under normal conditions, as it will cause the indoor unit’s thermostat function to operate incorrectly.
DIMENSIONS MODEL : AGG09LVCA, AGG12LVCA, AGG14LVCA (Unit : mm) Side view Front view INSTALLATION PLACE 10 cm or more 8 cm or more 8 cm or more 5 cm or more 15 cm or below from the floor AG ...
FAN PERFORMANCE AND CAPACITY 7-1. AIR VELOCITY DISTRIBUTION MODEL : AGG09LVCA, AGG12LVCA, AGG14LVCA Unit : m/s TOP VIEW Conditions: FLOW CONTROL PANEL : Horiz. LOUVER : Center Fan speed : HI Operation mode : FAN Fan select : UPPER&LOWER : UPPER FAN : LOWER FAN LOWER...
7-2. AIRFLOW MODEL : AGG09LVCA, AGG12LVCA Cooling Number of rotations Fan speed [r.p.m] Airflow (UPPER/LOWER) m³/h HIGH 1190/1000 m³/h 1000/850 m³/h 820/690 m³/h QUIET 660/560 zHeating Number of rotations Fan speed [r.p.m] Airflow (UPPER/LOWER) m³/h HIGH 1240/1040 m³/h 1040/880...
Page 16
MODEL : AGG14LVCA Cooling Number of rotations Fan speed [r.p.m] Airflow (UPPER/LOWER) m³/h HIGH 1330/1120 m³/h 1100/930 m³/h 890/750 m³/h QUIET 660/560 zHeating Number of rotations Fan speed [r.p.m] Airflow (UPPER/LOWER) m³/h HIGH 1330/1120 m³/h 1100/930 m³/h 860/730 m³/h...
ELECTRIC CHARACTERISTICS Model Name AGG09LVCA AGG12LVCA AGG14LVCA Voltage 230 ~ Power Supply Frequency Max Operating Current Connection Cable Wiring Spec. * Limited wiring length *: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005. - (01 - 17) -...
SAFETY DEVICES Model AGG09LVCA Protection form AGG12LVCA AGG14LVCA Circuit protection Current fuse (PC board) 250 V 3.15 A Terminal protection Current (thermal) fuse 250 V 3 A OFF : 150 ± 15 °C Fan motor protection Terminal protection program ON : 120 ± 15 °C - (01 - 18) -...
EXTERNAL INPUT & OUTPUT Connector INPUT OUTPUT REMARKS CN14 Control input See external input/output settings for details. CN20 Operation status output 11-1. EXTERNAL INPUT CONTROL INPUT (Operation/Stop or Forced stop) The air conditioner can be remotely operated by means of the following on-site work. "Operation/Stop"...
Page 23
Parts (Optional) Parts name Model name External connect kit UTY-XWZX - (01 - 20) -...
11-2. EXTERNAL OUTPUT OPERATION STATUS OUTPUT An air conditioner operation status signal can be output. Circuit diagram example Indoor unit Connected unit control PC board Connector Ex.) Relay unit Ex.) Display DC 24 V Relay power supply Relay spec.: Max.DC 24 V, 10 mA to less 10 m*...
FUNCTION SETTINGS 12-1. INDOOR UNIT (Setting by remote controller) • The function settings of the control of the indoor unit can be changed by this procedure according to the installation conditions. Incorrect settings may cause an indoor unit malfunction. • After turning on the power, perform the Function Setting according to the installation conditions by using the remote controller.
Page 26
CONTENTS OF FUNCTION SETTING • Follow the instructions in the Local Setup Procedure, which is supplied with the remote controller, in accordance with the installed condition. After turning on the power, perform the Function Setting by using the remote controller. •...
Page 27
4) Room temperature control for heating Depending on the installed environment, correction of the room temperature sensor may be required. Select the appropriate control setting according to the installed environment. ( . . .Factory setting) Setting Description Function Number Setting Value Standard ...
Page 28
8) External input control "Operation/Stop" mode or "Forced stop" mode can be selected. ( . . .Factory setting) Setting Description Function Number Setting Value Operation/Stop mode (Setting prohibited) Forced stop mode 9) Indoor unit fan control for energy saving for cooling Enables or disables the power-saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation.
Page 29
REMOTE CONTROLLER SIGNAL CODE SETTING Use the following steps to select the signal code of the remote controller. (Note that the air conditioner cannot receive a signal code if the air conditioner has not been set for the signal code.) Press the START/STOP button until only the clock is displayed on the remote controller display.
OPTIONAL PARTS 13-1. CONTROLLERS Exterior Parts name Model No. Summary Large and full-dot liquid crystal Wired remote screen, wide and large keys UTY-RVN M controller easy to press, user-intuitive arrow key. The room temperature can be Wired remote controlled by detecting the UTY-RNN ...
SPECIFICATIONS Type INVERTER HEAT PUMP Model name AOG09LVCA AOG12LVCA AOG14LVLA Power source 230V~ 50Hz Available voltage range 198 - 264V~ 50Hz Starting current Cooling 1,680 1,910 Airflow rate Heating 1,490 1,680 1,750 Type × Q'ty Propeller fan × 1 Propeller fan × 1 Propeller fan ×...
DIMENSIONS MODEL : AOG09LVCA, AOG12LVCA (Unit : mm) MODEL : AOG14LVLA INSTALLATION PLACE 100 mm or more 600 mm or more 100 mm or more 250 mm or 200 mm or more more 50 mm or more - (02 - 02) -...
AIRFLOW MODEL : AOG09LVCA Cooling Number of rotations Airflow (r.p.m.) 1,680 Heating Number of rotations Airflow (r.p.m.) 1,490 MODEL : AOG12LVCA Cooling Number of rotations Airflow (r.p.m.) 1,680 Heating Number of rotations Airflow (r.p.m.) 1,680...
Page 42
MODEL : AOG14LVLA Cooling Number of rotations Airflow (r.p.m.) 1,910 1,124 Heating Number of rotations Airflow (r.p.m.) 1,750 1,030 - (02 - 10) -...
ELECTRIC CHARACTERISTICS Model name AOG09LVCA AOG12LVCA AOG14LVLA Voltage 230 ~ Power supply Frequency *1) Max operating current 10.0 13.5 Starting Current Main Fuse (Circuit breaker) Current *2) Wiring Spec.: Power Cable 1.5 - 2.5 *3) Limited wiring length : *1) The maximum current is the total current of indoor unit and outdoor unit. *2) Wiring Spec.: Selected Sample (Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
SAFETY DEVICES Model Protection form AOG09LVCA AOG12LVCA AOG14LVLA 250V 20A Current fuse (Near the terminal) 250V 5A Circuit protection 250V 15A Current fuse (Main printed circuit board) 250V 3.15A OFF: 100 °C Thermal protection Fan motor protection program ON: 95 °C Thermal protection OFF: 110°C...