Space Requirements - KitchenAid Electric 30-inch Installation Instruction

Hide thumbs Also See for Electric 30-inch:

Advertisement

1
Befotw you begin
Read these instructions
completely and carefully.
If followed, they will simplify the installation job.
IMPORTANT:
Observe all governing codes and ordinances.
Failure to follow these instructions
could lead to
fire or electrical shock hazard.
A. Space requirements
AB-
I
C
tEE
1
+
20
7"
Max.
+
t
Wall
Receptacle
I
v
-L-- -___
A
= 30" min. clearance
between
cooktop and bottom of an
unprotected
wood or metal
cabinet.
B
= Ei;l;h,Wween
counters:
303/8"
1
'1
C = Height of countertop:
355A3" to
36'3/16"
D
= Depth: 22%"
E
= Pigtail receptacle
location:
8" to 22" from either cabinet,
7" max. from floor.
To prevent discoloration
of base
cabinet, front of oven frame must
extend at least W' beyond front
surface of cabinets.
Do not seal range to cabinets.
The copper power cord (pigtail) must
run downward,
left or right to the wall
receptacle
to avoid pinching the cord
between rear portion of the range
and wall.
The back of a free-standing
range
may be installed against a vertical
wall. Sides may be installed against
base cabinets or against vertical
walls extending
above upper edge of
the cooktop.
CAUTION:
Reaching over heated surface elements causes
risk of being burned. To reduce risk, installation
of
cabinet storage above surface units should be
avoided.
2
If cabinets are already provided, reduce hazard
by installing
a range hood. Hood should project
horizontally
beyond bottom of cabinets by a
minimum of 5 inches.