Download Print this page

Panasonic HHR330APH Datasheet

Nickel metal hydride batteries

Advertisement

Quick Links

NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET
HHR330APH
Cylindrical L-Fat A size (HR 18/67)
Dimensions (with Tube)
18.2
(
( )

Specifications

Diameter
Height
Approximate
Weight
Nominal Voltage
Average
Discharge
1
Capacity
Rated (Min.)
Approx. Internal impedance
at 1000Hz at charged state.
Standard
3
Rapid
Charge
Low Rate
Standard
Charge
Rapid
Discharge
< 1 year
< 6 months
Storage
< 1 month
< 1 week
1
After charging at 0.1It for 16 hours, discharging at 0.2It.
2
For reference only.
3
Need specially designed control system
Control System:
dT/dt cut-off; 1 to 2°C/min
- V cut-off; - V per cell = 5 to 10 mV
T-control; T=65°C
Rapid charger timer; 2.4h (at 1.25a)
Trickle timer; within 2h
4
With control system
Battery performance and cycle life are strongly affected by how they
are used. In order to maximize battery safety, please consult Panasonic
when determining charge / discharge specs, warning label contents and
unit design.
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to
modification without notice. Contact Panasonic for the latest information.
+
0
-
0.7
+
)
+
0
67.0
-
1.5
mm
inch
18.2+0/-0.7
0.72+0/-0.03
67.0+0/-1.5
2.64+0/-0.06
Grams
Ounces
60
2.12
1.2V
2
3300 mAh
3200 mAh
5.5m
330mA x 16hrs.
4
1650mA x 2.4 hrs.
165mA x 32 hrs.
110mA x 48 hrs.
C
F
˚
˚
14˚F to 140˚F
-10˚C to 60˚C
14˚F to 113˚F
-10˚C to 45˚C
-10˚C to 60˚C
14˚F to 140˚F
-20˚C to 35˚C
-4˚F to 95˚F
-20˚C to 45˚C
-4˚F to 113˚F
-4˚F to 131˚F
-20˚C to 55˚C
-20˚C to 65˚C
-4˚F to 149˚F
NICKEL METAL HYDRIDE HANDBOOK
Typical Charge Characteristics
(mm)
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0
Typical Discharge Characteristics
120
110
100
90
80
70
60
50
Charge: 330mA(0.1 It) 16hrs
Disharge: 660mA(0.2 It),cut off voltage 1.0V
40
Disharge Temperature: 25˚C
30
- 20
1.8
1.6
1.4
1.2
1.0
0.8
0
Note:
[It] was previously expressed as [C]. [It] is an IEC standard expression
for the amount of charge or discharge current and is expressed as:
It(A) = Cn (Ah)/1h.
• [It] is the reference test current in ampres
• [Cn] is the rated capacity of the cell or battery in Ampere-hours.
n = the time base [hours] for which the rated capacity is declared
Charge: 330mA(0.1 It) 16hrs.
2
4
6
8
10
12
14
Charge Time (hours)
- 10
0
10
20
30
40
Temperature (˚C)
Charge: 330mA(0.1 It) 16hrs, 20˚C
Discharge Temperature: 20˚C
5
10
15
20
Discharge Time (min.)
AUGUST 2005
-10˚C
25˚C
60˚C
16
18
20
50
60
70
10A
20A
25
30

Advertisement

loading