B
This command takes a pre-configured String (defined below) containing the
new memory contents and a CRC (written by the EGPWS) and writes them to
the Configuration Module's EEPROM.
4.2.3.3 Configuration String Format
The EGPWS requires a string of configuration information to be written to the
configuration module memory when requested from the keyboard monitor.
Example String: = CUW 0/11 0 1 0 0 0 2 2 0 5 0/ (Space after cuw, cate-
gory and each number if there is no separator)
Where the first 0 reflects the string version, the next number is the number of
categories and the remaining numbers before the second separator reflect the
ID for each of the categories.
String breakdown Explanations:
CUW = The command to write
0
= String Version
/
= Separator
11
= the number of categories
0
= Category #1 ID = 0
1
= Category #2 ID = 1
0
= Category #3 ID = 0
0
= Category #4 ID = 0
0
= Category #5 ID = 0
0
= Category #6 ID = 0
2
= Category #7 ID = 2
2
= Category #8 ID = 2
0
= Category #9 ID = 0
5
= Category #10 ID = 5
0
= Category #11 ID = 0
/
= Separator
Rev 3, August/2002
(TSO-C151a Class B curve set)
(Altitude Encoder with 500 ohm
Temperature Probe)
(GPS, Internal GPS Express RS-232)
(Display select = ASPB)
(I/O Discrete Type Select = Basic, Lamp
format 2)
(Audio Menu Select = Basic)
(Audio Output Level = -12dB)
(Altitude Monitor Option Select = Disable)
(TA&D Alternate Pop Up = False)
(Altitude and Heading Source = Reserved)
(Display Options = Classic Fixed Wing)
10609I03 CDL
KMH 880/KTA 870
Page 4-3