Sealey SAC41.V2 Instruction Manual page 2

Air cooler/heater/air purifier/humidifier

Advertisement

2. SPECIFICATION
Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V
Cooler: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70W
Heater: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000W/2000W
Anion Density: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 million/cm³
Multifunction 4-in-1 unit comprising Air Cooler, Heater, Humidifier and Air Purifier. Features a 3-speed fan, adjustable airflow direction and
timer. Refrigerant-free cooling is achieved by evaporating water, which can be enhanced by adding ice. Fan-assisted heating function with two
settings. Air purification is achieved by negative ion generation and an activated carbon filter. Supplied with electronic remote control. Mounted
on castors for manoeuvrability.
3. OPERATION
3.1.
CONTROL PANEL FUNCTIONS.
3.1.1. Heat/Cool Air Selection Control (on side of unit - fig.1)
Before the heater functions can be used this lever must be moved to the HEAT position. When the cooling functions are required move
the lever to the COOL position.
3.1.2. Timer
By pressing the timer button, the timer can be set to switch off the unit, in periods of time from 0.5 to 7.5 hours in half hour increments. As you
press the button the four indicator lights above it will illuminate in different combinations. The time period selected is indicated by adding
together the time values above each illuminated light. To turn the timer off, advance the timer setting to 7.5 hours (all four lights illuminated),
then press the button once more and the timer is switched off.
NOTE: If the timer is not selected, the unit will continue to work in the mode that it is set, until the unit is switched off manually.
3.1.3. Wind
The direction of the air flow coming out of the unit is controlled by two sets of louvres. The horizontal louvres on the front of the
machine can be manually adjusted up or down. Behind these louvres is a second set of electrically driven vertical louvres which can be
made to oscillate from side to side by pressing the Wind button. An indicator light will illuminate above the button to show that the louvres are
working. To cancel the movement, press the button again. The indicator light will go out.
3.1.4. Speed
There are three speeds available: High, Medium, Low. Press the button to cycle through these until the desired speed is reached.
NOTE: In Heat mode, only two fan speeds are available: Medium and Low.
3.1.5. Heat
Before switching to the Heat function, make sure that the air flow control lever is moved to the HEAT position. This unit contains a special
heater with a Positive Temperature Coefficient element. Press the button to cycle through the available heating options. One press will
illuminate the PTC1 indicator which is equivalent to 1000Watts. A second press will illuminate both PTC1 and PTC2 indicators, which is
equivalent to 2000Watts. A third press switches the heater off.
3.1.6. Cool
Before switching to the cooling function make sure that the air flow control lever is moved to the COOL position. Press the button once to
activate the cooling function. The 'Icy Breeze' indicator light above the button will illuminate. To stop the cooling function, press the button
again and the indicator light will go out.
3.1.7. On/Off
When the unit is plugged in, it will beep to show that it is in Standby mode. Switch the unit on by pressing the ON/OFF button. The power
indicator above the button will illuminate.
fig.1
© Jack Sealey Limited
Maximum Air Flow: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .350mtr³/hr
Cooling Water Tank:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8.0ltr
Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6.5kg
Original Language Version
SAC41.V2
Issue: 2(L) - 31/12/13