Configuration
Example of an FTP client configuration file
# This is a comment
TIMESTAMP=3D2C4E48
FILETYPE=FDB
FILEFORMAT=01
00|W|1|VB0|station99_VB0_1.dump|192.168.232.13|FTP_Server_2|3AqW&4Cv
01|W|1024|VB256|/station36_VB256_1024.data|192.168.232.13|FTP_Server_2|3AqW&4Cv
02|R|5|VB2|/data/station36_VB2_5.err|192.168.232.2|FTP_Server_3|asw345Df
03|R|23|VB11|/flash:/dat/CPU10_VB11_23.dat|192.168.162.65| FTP_Server_4| W9vQ}G cfH
04|||||||
05|||||||
06|||||||
07|D|||/data/station36_VB2_5.err|192.168.232.2|FTP_Server_3|asw345Df
08|||||||
.....
30|||||||
31|||||||
END
# End of File
Note
− Commentary is added to the file with the # character.
− A blank user entry in the .fdb file is stored as follows: xx||||||| (whereby xx
stands for the running FTP client job number)
− The last character of a line is \n.
− All characters between 0x21
name, user name and password if this is acceptable to the communication
partners involved.
− The following additional restrictions apply to directory and file names.
Not supported: blanks ; \ ; / ; | ; < ; > ; " ; : ; * and ?
− Blank lines are not permitted.
Caution
With a READ action, <Number of bytes> is usually between 0 and 10240 (maxi-
mum with the CPU 226XM).
When the value 0 is entered, the CP 243-1 IT does not check the actual file length.
All data in the file are read and, starting with <DB start address>, copied to the DB
of the S7-200 CPU if this does not exceed the memory size.
If the number of data bytes to be read is not 0, the CP 243-1 IT checks during the
data transmission to determine whether the specified number of bytes has already
been reached and, if so, concludes the copy procedure. This procedure offers a
high degree of security and protects the unsecured memory area of the S7-200
CPU from being overwritten accidentally.
88
and 0x7E
can be used for path, file
HEX
HEX
03/03
CP 243-1 IT
J31069-D0429-U001-A0-7618