  • Page 1: Network Interface Unit

    Network Interface Unit Operating Instructions WJ-NT104 Model No. O P E R A T LIN K RC V XM T N e tw o rk In te rf a c e U n it W J -N T 1 0 4 Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use.
  • Page 2 Caution: Before attempting to connect or operate this product, please read the label on the bottom. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
  • Page 3: Table Of Contents

    PPP (Point to Point Protocol) Type Connection ... 11 PREPARATIONS ... 12 LAN Type Connection ... 12 WJ-NT104 Setup ... 15 PPP Type Connection 1 (P to P ACCESS) ... 16 PPP Type Connection 2 (NETWORK ACCESS) ... 22 MAIN PAGE AND CONTROLS ... 25 Main Page and Control Windows ...
  • Page 4: Preface

    HTML file using FTP (File Transfer Protocol). • Designed for rack mounting using the optional WV- Q204/1 mounting brackets. Use of the optional WV-Q204/2 mounting brackets per- mits mounting up to two WJ-NT104 units in a rack side by side. Homepage...
  • Page 5: Precautions

    PRECAUTIONS • Refer all work related to the installation of this prod- uct to qualified service personnel or system installers. • Do not attempt to disassemble the appliance. To prevent electric shock, do not remove screws or covers. There are no user-serviceable parts inside. Contact qualified service personnel for maintenance.
  • Page 6: Major Operating Controls And Their Functions

    MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS Front View Rear View q Operate indicator [OPERATE] Is on while the power of the WJ-NT104 is turned on. w Link indicator [LINK] Lights when the unit is connected to a normally operat- ing network.
  • Page 7 RESET button again to restart. • SW2 To return the HTML file, JPEG or other image data stored in the WJ-NT104 to the factory default set- tings. The IP address and other setup data will not be initialized.
  • Page 8: Installations

    1. Remove the four rubber feet by removing the four screws from the bottom of the WJ-NT104. Mounting one WJ-NT104 with the WV-Q204/1 2. Fix the mounting brackets (large and small) on both sides of the WJ-NT104 with the eight supplied screws (M3x8) as shown below.
  • Page 9 3. Install the WJ-NT104 with the rack mounting brackets in the rack by using four screws (not included). Cautions: • Do not block the ventilation opening or slots in the cover to prevent the appliance from overheating. Always keep the temperature in the rack within +50°C (122°F).
  • Page 10: System Connections

    SYSTEM CONNECTIONS The WJ-NT104 can be operated either in a LAN type connection to an Ethernet or a PPP type connection to a public line via a modem/terminal adapter (TA). LAN Type Connection For LAN type connection, it is necessary to set the IP address, netmask, and default gateway of the WJ-NT104 according to your LAN environment.
  • Page 11: Ppp (Point To Point Protocol) Type Connection

    In this configuration, a client PC accesses the WJ-NT104 via a public line using PPP (Point to Point Protocol). With PPP MODE in the NETWORK SETUP dialog box set to P to P ACCESS, the WJ-NT104 can be accessed by a PC running Windows95, for example.
  • Page 12: Preparations

    Requires a PC satisfying the following conditions. LAN Type Connection The figure below shows how the WJ-NT104 can be connected directly to a PC for testing before it is connected directly to a network. The connection can also be made via a hub.
  • Page 13 PC Setup The factory default settings of the WJ-NT104 are as fol- lows: IP address Netmask Default gateway For a client PC to access WJ-NT104 factory default set- tings, set the IP address of the PC to 192.168.0.XX (XX means any number from 2 to 254 except 10).
  • Page 14 NT104's home page. If there is a camera input, it also displays the camera image. y Click [button] on the home page and verify the func- tions of the WJ-NT104. For details on home page operations see MAIN PAGE on page 30.
  • Page 15: Wj-Nt104 Setup

    WJ-NT104 Setup First, it is necessary to set an IP address for the WJ-NT104 according to the operating environment. Consult your network administrator for the address to set. IP Address Setting via LAN Connection q On the Location bar, enter http://192.168.0.10/hwset- up.html to display the ADMINISTRATOR SETUP...
  • Page 16: Ppp Type Connection 1 (P To P Access)

    To set up the PPP connection, access the WJ-NT104 from a PC via a LAN and open the ADMINISTRATOR SETUP PAGE. If the WJ-NT104 is already connected to a LAN, go to the Location bar and specify http://192.168.0.10 (or IP address set previ- ously)/hwsetup.html to display the ADMINISTRATOR SETUP PAGE.
  • Page 17 The WJ-NT104 is switched from LAN connection mode to PPP connection mode. u Connect the RS-232C port on the rear panel of the WJ-NT104 to the RS-232C port on the modem/TA with a RS-232C cable, and access the WJ-NT104 from a client PC via the modem/TA.
  • Page 18 Access Procedures Follow these procedures to access the WJ-NT104 from a PC running Windows95 or Windows98 via a PPP type connection. 1. Preparations q Check that the following software is installed in the PC. • TCP/IP protocol The TCP/IP protocol comes as an accessory with Windows95/98. Access the Control Panel If TCP/IP Dial-Up Adapter is not listed, you need to install the TCP/IP protocol.
  • Page 19 w Double-click the Make New Connection icon. e Type a name for the PC and select a modem. Then click the [Next] button. r Enter the phone number and click the [Next>] button. A message appears, reading [You have successfully created a new Dial-Up Networking connection called:]. t Click the [Finish] button.
  • Page 20 y Click the [Server Type...] button. u For Type of Dial-up Server, select PPP: Windows95, Windows NT 3.5, Internet (for Windows95), or PPP: Windows95/98, Windows NT 4.0, Internet (for Windows98). i Remove all checks in the Advanced options field. o Check TCP/IP in the Allowed network protocols field. !0 Click the [TCP/IP Settings...] button to display the TCP/IP Settings dialog box.
  • Page 21 The Connection Established dialog box is displayed after a short delay to indicate that the connection is under way. * With some versions of Windows95 this dialog box is not displayed. e Double-click the icon shown on the task bar to display the Connected to WJ-NT104 dialog box which indicates that the connection is under way.
  • Page 22: Ppp Type Connection 2 (Network Access)

    Check TCP/IP in the Allow remote clients running field. y Check Allow any authentication including clear test in the Encryption settings field. RS-232C cable Modem/TA CSU/DSU WJ-NT104 Public lines RS-232C cable Modem/TA Dial-up server/ CSU/DSU router etc. (Windows95 etc.)
  • Page 23 u Click the [Configure...] button to display the RAS Server TCP/IP Configuration dialog box. i Check Entire network in the Allow remote TCP/IP clients to access field. o Check Use static address pool under Choose Cancel if you do not want to allow remote TCP/IP clients to dial in. !0 Set Begin and End of an address.
  • Page 24 2. Windows98 Setup If the Dial-Up Networking icon is not in My Computer, it is not installed. You can use the following procedure to install it. (1) Click the Start button, point to Settings, and then click Control Panel. (2) Double-click Add/Remove Programs. (3) Click the Windows Setup tab, click Communications, and then click the [Details] button.
  • Page 25: Main Page And Controls

    MAIN PAGE AND CONTROLS Main Page and Control Windows On the Location bar of the PC, type http://192.168.0.10 (or IP address set for WJ-NT104) to display the MAIN PAGE default window. The MAIN PAGE window is available in the following five modes: 1.
  • Page 26: Operation Modes

    • Unless a user changes channels, the last selected channel is used to continue transmission. A change of channel by one user causes the channels of the other users connected to the WJ-NT104 to be switched to that same channel. This means that the monitored picture may suddenly change to another.
  • Page 27 • This is an applied version of Random Input Selection Mode, used to change channels at specified intervals. Pan/tilt, zoom, and other camera functions cannot be controlled in this mode. CAMERA CAMERA CAMERA CAMERA WJ-NT104 OPERATE LINK RCV XMT Network Interface Unit WJ-NT104 WJ-NT104 OPERATE LINK RCV XMT Network Interface Unit WJ-NT104 Channel Selection...
  • Page 28: Pull Mode And Push Mode

    Java Script. Push Mode A request to send continuous images is sent from the PC to the WJ-NT104. The WJ-NT104 receives the newest image at set time intervals, and continuously sends the received images to the PC.
  • Page 29: Picture Quality Setup

    Picture Quality Setup Image Resolution The following four image resolutions (number of picture elements) are available. The higher the resolution, the larger the image and the lower the display speed. q 640 x 480 pixel w 640 x 240 pixel e 320 x 240 pixel r 160 x 120 pixel Note:...
  • Page 30: Main Page (Without Camera Control)

    INPUT SELECT These buttons are used to switch the images of up to four cameras. A change of channel by one user causes the channels of the other users connected to the WJ-NT104 to be switched to that same channel.
  • Page 31 Restores Multi Input Selection mode. w ALARM LIST Camera video input before and after alarm input can be temporarily stored in the internal memory of the WJ-NT104. For alarm display see ALARM LIST on page 37. e Live image display...
  • Page 32: Main Page (With Camera Control)

    These buttons are used to switch images of up to four cameras. w PRESET SELECT To move the combination camera (option) connected to the WJ-NT104 to any of 8 preset position numbers. To register preset positions refer to the CAMERA MENU SETUP on page 53. e ALARM LIST...
  • Page 33 i IRIS The connected combination camera (option) can be controlled to close or open the iris by clicking the [OPEN] or [CLOSE] button under IRIS. Clicking the [OPEN] or [CLOSE] button will open or close the cam- era iris for a specified time, after which the operation is released automatically.
  • Page 34 Fixed Input Selection Mode q PRESET SELECT To move the combination camera (option) connected to the WJ-NT104 to any of 8 preset position numbers. To register preset positions refer to the CAMERA MENU SETUP on page 53. w ALARM LIST...
  • Page 35 PRESET SELECT To move the combination camera (option) connected to the WJ-NT104 to any of 8 preset position numbers. To register preset positions refer to the CAMERA MENU SETUP on page 53.
  • Page 36 u ZOOM The connected combination camera (option) can be zoomed by clicking the [TELE] or [WIDE] button under ZOOM. Clicking the [TELE] or [WIDE] button will operate the camera in telescopic or wide-angle mode for a speci- fied time, after which the mode is released automatical- ly.
  • Page 37: Alarm Function

    ALARM LIST Window On the Location bar, type http://192.168.0.10 (or IP address set for WJ-NT104)/almindex.html, or click the ALARM LIST button on the MAIN PAGE to display the ALARM LIST window. The window displays a list of alarm input dates, times and channels.
  • Page 38: Alarm Recording

    ALARM Recording The WJ-NT104 records images before and after an alarm is activated and notifies the user of alarm input. Alarm images can be recorded in the following three modes: Single Frame Recording mode When an alarm is received, the alarm image is captured and saved as a still image after the specified delay time.
  • Page 39: Alarm Notice

    ALARM NOTICE The WJ-NT104 can notify the user of an alarm event. The notice is sent either by Panasonic original protocol, e-mail (SMTP client) or a combination of both. E-Mail Notice Mail is sent to the mail server using SMTP (Simple Mail Transfer Protocol).
  • Page 40: Setup Procedures

    [SET & REBOOT] button Clicking this button stores the settings made on this page in the WJ-NT104. Remember, however, that any recorded alarm data will be deleted. q MODE SETUP To set the default page when a file name is specified.
  • Page 41: Mode Setup

    MODE SETUP On the ADMINISTRATOR SETUP PAGE, click the MODE SETUP button to display the MODE SETUP window. Select the operation mode, image quality and camera control. q VIDEO INPUT SELECTION MODE Select an operation mode for the camera displayed on the monitor.
  • Page 42 NT104. The same value is applied for live images and alarm images. The factory default setting is 320x240 pixels i IMAGE QUALITY Set the image quality for images from the WJ-NT104. The same value is applied for live images and alarm images. The factory default setting is FINE.
  • Page 43: Network Setup

    Used when PPP mode is on P to P ACCESS. Enter the IP address of the PC which calls and access- es the WJ-NT104. The PC's IP address must be set to Obtain an IP automatically. The factory default setting is 192.
  • Page 44: Alarm Setup

    ALARM SETUP On the ADMINISTRATOR SETUP PAGE, click the ALARM button to display the ALARM SETUP window. q ALARM RECORDING/LOG Set the alarm recording function to ON or OFF. w ALARM RECORDING MODE Select on alarm image recording mode. e OVERWRITE When YES is marked, old alarm images are overwritten by new alarm images.
  • Page 45 Accepts an NC alarm signal close: Accepts an NO alarm signal !4 SET button Clicking this button saves the settings in the WJ-NT104. !5 ALARM NOTICE (SMTP E-MAIL) To use the e-mail notice function, select YES. !6 SERVER ADDRESS Specify the address of the mail server to which mail is sent directly from the WJ-NT104.
  • Page 46: Serial Port Setup

    SERIAL PORT SETUP On the ADMINISTRATOR SETUP PAGE, click the SERIAL PORT button to display the SERIAL PORT SETUP window. Specify whether to use the RS-232C or RS-485 interface, and set the communication parameters. q TYPE (RS-232C) Set up the RS-232C port usage. Select NONE, MODEM/TA, WJ-SX550A, WJ-FS616, WJ-DR200 or Serial Through.
  • Page 47: Modem Setup

    Select the type of telephone line to use. The factory default setting is TONE. r LOCAL TELEPHONE NUMBER Set a telephone number for the WJ-NT104. t DESTINATION TELEPHONE NUMBER Set the destination telephone numbers in case the alarm notice function is used.
  • Page 48: User Setup

    Even if USER AUTHORIZATION is set to OFF, host authorization is necessary to access the pages exclu- sive to your network administrator, or to use the FTP function and PPP connection (to call the WJ-NT104). The factory default setting is OFF. w USER REGISTRATION Set USER NAME, PASSWORD, and ACCESS LEVEL.
  • Page 49: Host Setup

    HOST SETUP On the ADMINISTRATOR SETUP PAGE, click the HOST button to display the HOST SETUP window. Use this window to register or delete hosts that can be accessed without user authorization. q HOST AUTHORIZATION Set HOST AUTHORIZATION to OFF or ON. The factory default setting is OFF.
  • Page 50: Ftp Client Setup

    Specifies the IP address of the FTP server to which images are sent directly from the WJ-NT104. w USER NAME Specifies the user name when the WJ-NT104 logs in to FTP server. e PASSWORD Specifies the password when the WJ-NT104 logs in to FTP server.
  • Page 51 DATE/TIME mode: added digits (month, date, hour, minute, second, and last 2-digit year). Added MMDDhhmmsssYY (for example, 0123134500 101 for January 23 13:45:00.1, 2001) SEQUENTIAL NUMBER(MAX FIXED) mode: added number 00001 to 65535 automatically. SEQUENTIAL NUMBER(MAX VARIABLE) mode: added number between 00001 to max.(your setting number till 65535).
  • Page 52: Date & Time Setup

    DATE & TIME SETUP On the ADMINISTRATOR SETUP PAGE, click the DATE/TIME button to display the CLOCK SETUP window. Use this window to adjust the internal clock of the device. q DATE Set a date in the order of YY/MM/DD (for example, 99/01/23 for January 23, 1999).
  • Page 53: Camera Menu Setup

    CAMERA MENU SETUP On the ADMINISTRATOR SETUP PAGE, click the CAMERA MENU button to display the CAMERA MENU SETUP win- dow. The CAMERA MENU SETUP function is available in RANDOM INPUT SELECTION MODE and FIXED INPUT SELEC- TION MODE, but not in MULTI INPUT SELECTION MODE. The cameras (option) can be set by remote control from this page.
  • Page 54: Utility Software

    NT4.0 installed, and have an RS-232C port. Before installing the Utility Software provided, read the Readme.txt file on Utility Software disc. q Connect the RS-232C port on the front of the WJ-NT104 and the RS-232C port of the PC with an RS-232C cable.
  • Page 55 Request timed out. • If the WJ-NT104 responds as below, the network setup of the PC may be wrong. Correct the setup (e.g., change the IP address to 192.168.0.2 and the sub netmask to 255.255.255.0), and enter the ping command again.
  • Page 56: Camera Menu Setup

    This is software to control the camera menu of the WV-CS654 and CS854 (optional). It allows a user to open the menu of a camera connected to the WJ-NT104 with a coaxial cable and select preset position and other camera settings.
  • Page 57: Access Authorization

    Administrator (Level 1) • Access to and setup of ADMINISTRATOR SETUP PAGE • Rewriting data stored in the WJ-NT104 using FTP (File Transfer protocol) • Controlling cameras and other equipment connect- ed to the WJ-NT104 • Monitoring live images •...
  • Page 58: Registration

    Enter the host IP address as a dotted (.) notation, for example. 192.168.0.10. specified. The host IP address "0.0.0.0" is invalid. Select (mark) any of access levels 1 to 4. WJ-NT104 Authorized Functions Initially there are no The host name cannot be Operation Request...
  • Page 59: Extension Functions

    WJ-FS616 Video Multiplexer Control Connection (1) Connect MULTISCREEN OUT on the rear of the WJ-FS616 to VIDEO IN 1 on the rear of the WJ-NT104. (2) Connect the RS-232C ports of both units with a RS-232C cable. • Fixed Input Selection Mode In this mode, only images from the MULTISCREEN OUT connector of the Video Multiplexer are available.
  • Page 60 WJ-FS616 to any of 8 preset positions. e ALARM LIST Any image before or after alarm input can be temporar- ily stored in the internal memory of the WJ-NT104. For alarm display see ALARM LIST on page 37. r CAMERA SELECT (Bottom window panel) To select a camera (camera 1 to 16) connected to the WJ-FS616.
  • Page 61: Wj-Sx550A/B/C Matrix Switcher Control

    (2) Connect the RS-232C ports (of WJ-SX550A/B/C and WJ-NT104) with a RS-232C cable. You can also connect the CONTROL DATA port on the rear of the WJ-SX550A/B/C to the RS-485 connectors on the rear of the WJ-NT104. • Random Input Selection Mode For VIDEO INPUT SELECTION MODE under OPERATION MODE SELECT, mark RANDOM INPUT SELECTION MODE.
  • Page 62 WJ-SX550A Matrix Switcher to be connected to the video input connector on the WJ-NT104 network inter- face unit. The status when selecting VIDEO-INPUT (at WJ-NT104) in the above table is the same as when a monitor compatible with the WJ-SX550A is selected.
  • Page 63 WJ-SX550A to any of 8 preset positions. r ALARM LIST Any image before and after alarm input can be tem- porarily stored in the internal memory of the WJ-NT104. For alarm display see ALARM LIST on page 37. t CAMERA SELECT (Bottom window panel) To select a camera (CAMERA 1 to 128) connected to the WJ-SX550A.
  • Page 64: Wj-Dr200 Av Disk Recorder Control

    (1) Connect CAMERA 1 and 2 to the VIDEO IN 1 and 2 connectors on the rear of the WJ-NT104. (2) Connect the VIDEO OUT 1 and 2 connectors on the rear of the WJ-NT104 to the VIDEO IN A and B connectors of the WJ-DR200.
  • Page 65 Setup In the SERIAL PORT SETUP window, set TYPE under RS-232C to "WJ-DR200". Set the same communication parameters as for the WJ-DR200 AV Disk Recorder. (For further details refer to the operation manual of the WJ-DR200 AV Disk Recorder.) Control Operation On the Location bar, type the URL http://192.168.0.10/drindex.html to access the WJ-DR200 OPERATION VIEW window for the AV Disk Recorder.
  • Page 66 e FIND To directly specify and play back a recorded frame. r UP/Next Frame Click in paused playback to advance the playback operation one step to the next frame. Also moves the cursor up one line in the recording list or thumbnails.
  • Page 67: Wj-Hd100 Digital Disk Recorder Control

    WJ-HD100 Digital Disk Recorder Control It is enabled control of the WJ-HD100 disk recorder from the PC via the WJ-NT104 Network Interface Unit. (disabled control with PSoData) Also refer to the operating instructions for the disk recorder together. Connections • Fixed input selection mode In this mode, only images from the MONITOR OUT connector of the disk recorder are available.
  • Page 68 q SETUP MENU ON Opens the setup menu of the WJ-HD100. w SETUP MENU OFF Closes the setup menu of the WJ-HD100. e ALARM RECALL ON Opens the alarm recall table. r ALARM RECALL OFF Closes the alarm recall table. t RIGHT Moves the cursor to the right.
  • Page 69: Wj-Hd500 Digital Disk Recorder Control

    (1) Connect CAMERA 2 and 3 to the VIDEO IN 2 and 3 connectors on the rear of the WJ-NT104. (2) Connect the VIDEO OUT 2 and 3 connectors on the rear of the WJ-NT104 to the VIDEO IN 2 and 3 connector of the disk recorder.
  • Page 70 (1) Connect CAMERA 2 and 3 to the VIDEO IN 2 and 3 connectors on the rear of the WJ-NT104. (2) Connect the VIDEO OUT 2 and 3 connectors on the rear of the WJ-NT104 to the VIDEO IN 2 and 3 connector of the disk recorder.
  • Page 71 q CAMERA SELECT To select a camera (camera 1 to 16) connected to the WJ-HD500. w MULTI-SCREEN SELECT Selects the multiscreen pattern to be displayed on the image display. e SETUP MENU ON Opens the setup menu of the WJ- HD500. r SETUP MENU OFF Closes the setup menu of the WJ-HD500.
  • Page 72: Contents Upload

    Mode Setup Switch “2” of the WJ-NT104. Be sure to back up the files before attempting to conduct such operations. • No directories can be prepared in the content memory interior.
  • Page 73: Control By Html Description

    Image display, camera operation, and alarm image display can be effected on the WWW browser by means of commands described in the HTML (Hyper Text Mark-up Language) file. The WJ-NT104 employs CGI (Common Gateway Interface) to carry out these functions. When using a function, the following syntax is used.
  • Page 74: Camera Operation

    HTML Sample File [nsmainview1.html] <HTML> <HEAD></HEAD> <BODY BGCOLOR=”#FFFFCC”> <CENTER> <SCRIPT LANGUAGE=”JavaScript”> width=%W height=%H myDate = new Date(); document.write(“<IMG SRC=/cgi-bin/push?CH=%c&PAGE=”+myDate.getTime()+” WIDTH=”+width+” HEIGHT=”+height+ “ VSPACE=5></A>”); </SCRIPT> </CENTER> </BODY> </HTML z This is to request a new image in push mode. The page number of the argument is added for nullifying the cache. Camera Operation CGI functions related to camera operation The WV-CS654 and CS854 (optional) can be operated by using the following commands.
  • Page 75 HTML Sample File [mainpanel1.html] <HTML> <HEAD> </HEAD> <BODY BGCOLOR=”#FFFFCC”> <CENTER> <!— TITELE LOGO IMAGE —> <IMG SRC=/nt10logo.jpg VSPACE=8> <SCRIPT LANGUAGE=”JavaScript”> mode=%m <!— RANDOM=0,FIXED=1,MULTI=2 if(mode == 0) <!— RANDOM CAMERA SELECTION ONLY —> <!— CH SELECT FUNCTION —> document.write(“RANDOM INPUT SELECTION MODE”) document.write(“<P><TABLE BORDER=2 BORDERCOLOR=black WIDTH=90% BGCOLOR=#DCfeff>”) document.write(“<TR>”) document.write(“<TH BORDER=2 COLSPAN=4 BGCOLOR=black><FONT SIZE=3 COLOR=#DCfeff>”)
  • Page 76 <!— QUAD SCREEN —> document.write(“<P><TABLE BORDER=3 BORDERCOLOR=black WIDTH=90% BGCOLOR=#DCfeff>”) document.write(“<TR>”) document.write(“<TD BGCOLOR=black width=66% ><font SIZE=3 color=#DCfeff>”) document.write(“ QUAD SCREEN MODE</TD>”) document.write(“ BORDER=0></A></TD>”) document.write(“</TR>”) document.write(“</TABLE>”) </SCRIPT> </CENTER> <HR> <FONT SIZE=2 COLOR=BLUE> Copyright &#169 1998-1999 Matsushita Communication Industrial Co., Ltd.<BR> All rights reserved. </FONT>...
  • Page 77 HTML Sample File 2 [camctrl.html] <HTML> <BODY BGCOLOR=”#FFFFCC”> <CENTER> <TABLE BORDER=3 width=95% BORDERCOLOR=black BGCOLOR=”#DCFEFF”> <TR> <TH BORDER=3 COLSPAN=2 BGCOLOR=black><FONT SIZE=2 COLOR=”#DCFEFF”> ZOOM </FONT></TH> <TH BORDER=3 COLSPAN=3 BGCOLOR=black><FONT SIZE=2 COLOR=”#DCFEFF”> FOCUS </FONT></TH> <TH BORDER=3 COLSPAN=3 BGCOLOR=black><FONT SIZE=2 COLOR=”#DCFEFF”> IRIS </FONT></TH> <TH BORDER=3 COLSPAN=2 BGCOLOR=black><FONT SIZE=2 COLOR=”#DCFEFF”> AUTOPAN</FONT></TH>...
  • Page 78: Alarm Operation

    Alarm Operation CGI functions related to alarm Alarm images and log files recorded in the WJ-NT104 can be queried by using the following commands. CGI item Alarm log /cgi-bin/almlog file list Alarm /cgi-bin/almctrl image control (See page 80.) HTML Sample File [almctrl.html] <HTML>...
  • Page 79: Substitute Character Strings In Http Server

    z When the button is clicked, the first frame is displayed. x When the button is clicked, the frame immediately after alarm is displayed. c When the button is clicked, the last frame is displayed. v When the button is clicked, the image of the preceding frame is displayed. b When the button is clicked, the image of the next frame is displayed.
  • Page 80 cgi-bin/almctrl The substitute characters ordinarily used for HTML file get are not applicable. This substitute character is used in the same way as those for HTML file get. Item Substitute character Log number First frame number Frame number immediately after alarm Last frame Specified frame...
  • Page 81: Troubleshooting

    NT104 is connected? WJ-NT104 and client PC connected to the same subnet: • Are the IP addresses of the WJ-NT104 and the client PC set for the same subnet? • Is the browser set to [Use proxy server]? When accessing an NT104 on the same subnet, it is recommended to select [Do not use proxy server] for the IP address.
  • Page 82: Peripherals

    Push mode under the Netscape system Pull mode under the JavaScript system Pull mode under the JavaScript system Available image modes Recommend: Panasonic-made Camera capable of image output in compli- ance with the NTSC standard. WV-CS654, WV-CS854 Coaxial communication type. Both pan/tilt head control and lens control can be used via LAN from a remote PC.
  • Page 83: Specifications

    SPECIFICATIONS General Power Source: Ambient Operating Temperature: Ambient Operating Humidity: Dimensions: Weight: Input and Output Video Input: Video Output: Serial Control Port: Parallel Control Port: Image Resolution: Image Compression: Installed protocol: Camera Coaxial Control: LAN Interface: Security measures: AC Adapter Input: Output: Weight and dimensions shown are approximate.
  • Page 84 Panasonic Security and Digital Imaging Company A Division of Matsushita Electric Corporation of America Executive Office: One Panasonic Way 3E-7, Secaucus, New Jersey 07094 Regional Offices: Northeast: One Panasonic Way, Secaucus, NJ 07094 (201) 348-7303 Southern: 1225 Northbrook Parkway, Suite 1-160, Suwanee, GA 30024 (770) 338-6838...

Table of Contents