5-(1). Electrical life test
(3 A 250 V AC, resistive load)
Sample: ALD112, 6 pcs.
Operating speed: 20 cpm
Ambient temperature: room temperature
circuit:
250V AC
12V DC
60Hz
G
NO
COM
5-(2). Electrical life test
(3 A 30 V DC, resistive load)
Sample: ALD112, 6 pcs.
Operating speed: 20 cpm
Ambient temperature: room temperature
circuit:
12V DC
30V DC
G
NO
COM
For Cautions for Use, see Relay Technical Information .
Change of pick-up and drop-out voltage
100
90
80
70
60
50
40
30
20
10
0
0
Change of pick-up and drop-out voltage
100
90
80
70
60
50
40
30
20
10
0
0
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Pick-up voltage
Max.
Min.
Drop-out voltage
Max.
Min.
10
No. of operations, ×10
4
Pick-up voltage
Max.
Min.
Drop-out voltage
Max.
Min.
10
20
No. of operations, ×10
4
LD (ALD)
Change of contact resistance
100
90
80
70
60
50
40
30
20
10
0
0
No. of operations, ×10
Change of contact resistance
100
90
80
70
60
50
40
30
20
10
0
0
10
No. of operations, ×10
Max.
Min.
10
4
Max.
Min.
20
4

Advertisement