3 7 63 1515 0

6.4 ELECTRICAL ADJUSTMENT

1

VCO Free-running Adjustment

• Power ON
• None disc
• The position of TEMPO
slider is set to 0
• DOUT OFF
START
MAIN ASSY
VCO IN
GND
TE
L 13942296513
www
.
58
http://www.xiaoyu163.com
MAIN ASSY
VR601
Player
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
Objective : To optimize the VCO free-running frequency
When not properly adjusted :
• Master Tempo does not function normally.
• TEMPO display does not become the same as that
of actual voice tempo.
DC voltage
2.5±0.2V
Probe (10:1)
Q Q
3
6 7
1 3
1 5
co
.
9 4
2 8
CH1
CH2
(X)
(Y)
Oscilloscope
V: 50mV/div.
H: 10msec/div.
DC mode
0 5