8-6. Insulation Tests

On completion of disassembly and repair, measure the insulation resistance and conduct dielectric strength test.
Insulation resistance: 7 MΩ or more with DC 500 V megohm tester
Dielectric strength:

8-7. No-load Current Value

After no-load operation for 30 minutes, the current value should be as follows:
Voltage
110 V
Current (Max.)
1.4 A
AC 4,000 V/1 minute, with no abnormalities ................... 220 V --- 240 V
AC 2,500 V/1 minute, with no abnormalities ................... 110 V --- 120 V
115 V
120 V
1.4 A
220 V
1.3 A
0.7 A
--- 12 ---
(and 110 V for U.K. products)
(except U.K. products)
230 V
240 V
0.7 A